Abstract

The purpose of this study was to evaluate a commercial enzyme-linked immunosorbent assay (ELISA) for human von Willebrand factor antigen (vWF:Ag) with respect to its potential value in quantitating the protein in canine plasma. The assay was a sandwich technique using F(ab')2 fragments specific for von Willebrand factor (vWF) and a peroxidase conjugated rabbit anti-vWF second antibody, with a microplate as the support surface. Canine plasmas were assayed by ELISA, and by Laurell electroimmunoassay (EIA), our reference methodology. The ELISA had a within-day variation of 1.21-4.44% and a between-day variation of 0.85-4.88% depending on the level of vWF:Ag. The sensitivity of the assay was less than 0.1% vWF:Ag. The range of vWF:Ag concentrations in plasmas from 24 clinically normal dogs compared favorably with the range for the same plasmas when assayed by EIA (ELISA = 60-152% of normal; EIA = 50-142% of normal). In 121 canine plasmas with vWF:Ag concentrations (as assessed by EIA) ranging from undetectable levels (less than 6% of normal) to 142% of normal, there was good correlation with measurements made by ELISA (correlation coefficient = 0.835). It was concluded that this commercial ELISA technique could be used to provide reliable, same-day measurements of canine plasma vWF:Ag. Since it requires no special equipment other than a microplate reader and washer it is particularly suitable for laboratories lacking the electrophoretic expertise or equipment required for EIA.

Citing Articles

Type III von Willebrand's disease in Scottish terriers: A report of two cases.

Johnstone I, Norris A, Hirzer L Can Vet J. 1993; 34(11):679-81.

PMID: 17424324 PMC: 1686681.

References
1.
Johnstone I, Crane S . Determination of Canine Factor VIII-related Antigen Using Commercial Antihuman F VIII Serum. Vet Clin Pathol. 1980; 9(1):31-5. DOI: 10.1111/j.1939-165x.1980.tb00891.x. View

2.
HOYER L . Immunologic studies of antihemophilic factor (AHF, factor VIII). IV. Radioimmunoassay of AHF antigen. J Lab Clin Med. 1972; 80(6):822-33. View

3.
Ingerslev J . A sensitive ELISA for von Willebrand factor (vWf:Ag). Scand J Clin Lab Invest. 1987; 47(2):143-9. View

4.
Johnstone I, Norris A . A moderately severe expression of classical hemophilia in a family of german shepherd dogs. Can Vet J. 1984; 25(5):191-4. PMC: 1790574. View

5.
Bartlett A, DORMANDY K, Hawkey C, Stableforth P, Voller A . Factor-VIII-related antigen: measurement by enzyme immunoassay. Br Med J. 1976; 1(6016):994-6. PMC: 1639659. DOI: 10.1136/bmj.1.6016.994. View