Abstract

Sensitive and stable monitoring of heavy metals in seawater using screen-printed electrodes (SPE) is presented. The analytical performance of SPE coupled with square wave anodic stripping voltammetry (SWASV) for the simultaneous determination of Pb and Cd in seawater samples, in the low microgL(-1) range, is evaluated. The stripping response for the heavy metals following 2min deposition was linear over the concentration range examined (10-2000microgL(-1)) with detection limits of 1.8 and 2.9microgL(-1) for Pb and Cd, respectively. The accuracy of the method was validated by analyzing metal contents in different spiked seawater samples and comparing these results to those obtained with the well-established anodic stripping voltammetry using the hanging mercury drop electrode. Moreover, a certified reference material was also used and the results obtained were satisfactory.

Citing Articles

Thin Film Electrodes for Anodic Stripping Voltammetry: A Mini-Review.

Wygant B, Lambert T Front Chem. 2022; 9:809535.

PMID: 35186893 PMC: 8847685. DOI: 10.3389/fchem.2021.809535.


An innovative autonomous robotic system for on-site detection of heavy metal pollution plumes in surface water.

De Vito-Francesco E, Farinelli A, Yang Q, Nagar B, Alvarez R, Merkoci A Environ Monit Assess. 2022; 194(2):122.

PMID: 35075508 PMC: 8786775. DOI: 10.1007/s10661-021-09738-z.


Development of a Heavy Metal Sensing Boat for Automatic Analysis in Natural Waters Utilizing Anodic Stripping Voltammetry.

Yang Q, Nagar B, Alvarez-Diduk R, Balsells M, Farinelli A, Bloisi D ACS ES T Water. 2021; 1(12):2470-2476.

PMID: 34918010 PMC: 8669633. DOI: 10.1021/acsestwater.1c00192.


Electrochemical Characterization and Detection of Lead in Water Using SPCE Modified with BiONPs/PANI.

Okpara E, Nde S, Fayemi O, Ebenso E Nanomaterials (Basel). 2021; 11(5).

PMID: 34069149 PMC: 8156766. DOI: 10.3390/nano11051294.


Recent Advances in the Fabrication and Application of Screen-Printed Electrochemical (Bio)Sensors Based on Carbon Materials for Biomedical, Agri-Food and Environmental Analyses.

Hughes G, Westmacott K, Honeychurch K, Crew A, Pemberton R, Hart J Biosensors (Basel). 2016; 6(4).

PMID: 27690118 PMC: 5192370. DOI: 10.3390/bios6040050.