» Articles » PMID: 18807024

Stents for Intracranial Wide-necked Aneurysms: More Than Mechanical Protection

Overview
Journal Neuroradiology
Specialties Neurology
Radiology
Date 2008 Sep 23
PMID 18807024
Citations 57
Authors
Affiliations
Soon will be listed here.
Abstract

Treatment of wide-necked aneurysms by endovascular coil embolization usually requires mechanical aids in order to protect the parent artery from occlusion due to extension of coils or thrombosis. Endovascular stents are one tool that can be deployed to solve this essentially mechanical problem. The effect of a stent placed in the situation may also act as a hemodynamically active flow diverter. Endovascular stents used in other circumstances are prone to the unwanted side effect of neoinitmal proliferation, but this phenomenon should be seen as a potential asset for "aneurysmal stents" because it may lead to a reaction that contributes to vessel wall healing.

Citing Articles

Safety and efficacy of stent-assisted coil embolization with periprocedural dual antiplatelet therapy for the treatment of acutely ruptured intracranial aneurysms.

Lee I, Ha S, Lim D, Choi J Acta Neurochir (Wien). 2024; 166(1):216.

PMID: 38744753 DOI: 10.1007/s00701-024-06117-8.


Staged stenting strategy of acutely wide-neck ruptured intracranial aneurysms: A meta-analysis and systematic review.

Wei Y, Zhang X, Zhang R, Zhang G, Shang C, Chen R Front Neurol. 2023; 14:1070847.

PMID: 36816566 PMC: 9936144. DOI: 10.3389/fneur.2023.1070847.


Efficacy of pipeline embolization device vs. traditional coils in embolization of intracranial aneurysms: A systematic review and meta-analysis.

Li W, Xiao Z, Zhao K, Yang S, Zhang Y, Li B Front Neurol. 2022; 13:978602.

PMID: 36247783 PMC: 9558282. DOI: 10.3389/fneur.2022.978602.


Stent-assisted coiling using the Neuroform Atlas stent for treatment of aneurysms that recur after coil embolization.

Dong L, Wang J, Chen X, Zhang L, Zhao Z, Peng Q Front Neurol. 2022; 13:967942.

PMID: 36237610 PMC: 9552843. DOI: 10.3389/fneur.2022.967942.


Evaluation of Stent Apposition in the LVIS Blue Stent-Assisted Coiling of Distal Internal Carotid Artery Aneurysms : Correlation with Clinical and Angiographic Outcomes.

Kwon M, Ko Y, Kwon S, Kim C, Lee C J Korean Neurosurg Soc. 2022; 65(6):801-815.

PMID: 35728979 PMC: 9666237. DOI: 10.3340/jkns.2022.0021.


References
1.
Ohta M, Wetzel S, Dantan P, Bachelet C, Lovblad K, Yilmaz H . Rheological changes after stenting of a cerebral aneurysm: a finite element modeling approach. Cardiovasc Intervent Radiol. 2005; 28(6):768-72. DOI: 10.1007/s00270-004-7148-6. View

2.
Burleson A, Strother C, Turitto V . Computer modeling of intracranial saccular and lateral aneurysms for the study of their hemodynamics. Neurosurgery. 1995; 37(4):774-82; discussion 782-4. DOI: 10.1227/00006123-199510000-00023. View

3.
Wanke I, Doerfler A, Schoch B, Stolke D, Forsting M . Treatment of wide-necked intracranial aneurysms with a self-expanding stent system: initial clinical experience. AJNR Am J Neuroradiol. 2003; 24(6):1192-9. PMC: 8149018. View

4.
Rossitti S . Shear stress in cerebral arteries carrying saccular aneurysms. A preliminary study. Acta Radiol. 1998; 39(6):711-7. DOI: 10.3109/02841859809175503. View

5.
Tanaka N, Martin J, Tokunaga K, Abe T, Uchiyama Y, Hayabuchi N . Conformity of carotid stents with vascular anatomy: evaluation in carotid models. AJNR Am J Neuroradiol. 2004; 25(4):604-7. PMC: 7975609. View