Fluorescence-based Western Blotting for Quantitation of Protein Biomarkers in Clinical Samples

Overview
Journal Electrophoresis
Specialty Chemistry
Date 2008 Sep 23
PMID 18803224
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

Since most high throughput techniques used in biomarker discovery are very time and cost intensive, highly specific and quantitative analytical alternative application methods are needed for the routine analysis. Conventional Western blotting allows detection of specific proteins to the level of single isotypes while its quantitative accuracy is rather limited. We report a novel and improved quantitative Western blotting method. The use of fluorescently labelled secondary antibodies strongly extends the dynamic range of the quantitation and improves the correlation with the protein amount (r=0.997). By an additional fluorescent staining of all proteins immediately after their transfer to the blot membrane, it is possible to visualise simultaneously the antibody binding and the total protein profile. This allows for an accurate correction for protein load. Applying this normalisation it could be demonstrated that fluorescence-based Western blotting is able to reproduce a quantitative analysis of two specific proteins in blood platelet samples from 44 subjects with different diseases as initially conducted by 2D-DIGE. These results show that the proposed fluorescence-based Western blotting is an adequate application technique for biomarker quantitation and suggest possibilities of employment that go far beyond.

Citing Articles

Improving rigor and reproducibility in western blot experiments with the blotRig analysis.

Omondi C, Chou A, Fond K, Morioka K, Joseph N, Sacramento J Sci Rep. 2024; 14(1):21644.

PMID: 39284854 PMC: 11405887. DOI: 10.1038/s41598-024-70096-0.


Temporal kinetics of bovine mammary IgG secretion into colostrum and transition milk.

Schalich K, Reiff O, Nguyen B, Lamb C, Mondoza C, Selvaraj V J Anim Sci. 2021; 99(5).

PMID: 33715013 PMC: 8139318. DOI: 10.1093/jas/skab083.


Validating Antibodies for Quantitative Western Blot Measurements with Microwestern Array.

Koch R, Barrette A, Stern A, Hu B, Bouhaddou M, Azeloglu E Sci Rep. 2018; 8(1):11329.

PMID: 30054510 PMC: 6063895. DOI: 10.1038/s41598-018-29436-0.


Pannexin 2 protein expression is not restricted to the CNS.

Le Vasseur M, Lelowski J, Bechberger J, Sin W, Naus C Front Cell Neurosci. 2014; 8:392.

PMID: 25505382 PMC: 4243559. DOI: 10.3389/fncel.2014.00392.


A guide to modern quantitative fluorescent western blotting with troubleshooting strategies.

Eaton S, Hurtado M, Oldknow K, Graham L, Marchant T, Gillingwater T J Vis Exp. 2014; (93):e52099.

PMID: 25490604 PMC: 4354265. DOI: 10.3791/52099.