An Instrumented Implant for in Vivo Measurement of Contact Forces and Contact Moments in the Shoulder Joint

Overview
Journal Med Eng Phys
Date 2008 Sep 16
PMID 18789749
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

To improve implant design, fixation and preclinical testing, implant manufacturers depend on realistic data of loads acting on the shoulder joint. Furthermore, these data can help to optimize physiotherapeutic treatment and to advise patients in their everyday living conditions. Calculated shoulder joint loads vary extremely among different authors [Anglin C, Wyss UP, Pichora DR. Glenohumeral contact forces. Proc Inst Mech Eng [H] 2000;214:637-44]. Additionally the moments acting in the joint caused by friction or incongruent articular surfaces, for example, are not implemented in most models. An instrumented shoulder joint implant was developed to measure the contact forces and the contact moments acting in the glenohumeral joint. This article provides a detailed description of the implant, containing a nine-channel telemetry unit, six load sensors and an inductive power supply, all hermetically sealed inside the implant. The instrumented implant is based on a clinically proven BIOMET Biomodular shoulder replacement and was calibrated before implantation by using complex mathematical calculation routines in order to achieve an average measuring precision of approximately 2%.

Citing Articles

Force Sensor for Instrumented Patellar Prostheses: Development and Characterization.

Maioli V, Zauli M, Cappello A, Cristofolini L Sensors (Basel). 2025; 25(4).

PMID: 40006455 PMC: 11860769. DOI: 10.3390/s25041226.


Short humeral stem in total shoulder arthroplasty does not jeopardize primary implant stability.

Galteri G, Montanari S, Dozza G, Palanca M, Cristofolini L JSES Int. 2025; 9(1):212-218.

PMID: 39898196 PMC: 11784511. DOI: 10.1016/j.jseint.2024.09.021.


Maximum in-vivo joint contact forces double during active compared to assisted motion in the glenohumeral joint and decline long-term due to rotator cuff pathologies.

Harti L, Schrednitzki D, Damm P, Halder A Arch Orthop Trauma Surg. 2024; 144(7):2945-2954.

PMID: 38847837 DOI: 10.1007/s00402-024-05392-5.


Development of an implantable trapezium carpal bone replacement for measuring in vivo loads at the base of the thumb.

Crisco J, Henke J, McDermott D, Badida R, Morton A, Kalshoven J J Biomech. 2024; 165:112013.

PMID: 38401330 PMC: 10956735. DOI: 10.1016/j.jbiomech.2024.112013.


Advances in Wireless, Batteryless, Implantable Electronics for Real-Time, Continuous Physiological Monitoring.

Kim H, Rigo B, Wong G, Lee Y, Yeo W Nanomicro Lett. 2023; 16(1):52.

PMID: 38099970 PMC: 10724104. DOI: 10.1007/s40820-023-01272-6.