» Articles » PMID: 18672243

Whole Body Inverse Dynamics over a Complete Gait Cycle Based Only on Measured Kinematics

Overview
Journal J Biomech
Specialty Physiology
Date 2008 Aug 2
PMID 18672243
Citations 61
Authors
Affiliations
Soon will be listed here.
Abstract

This paper presents a three-dimensional (3D) whole body multi-segment model for inverse dynamics analysis over a complete gait cycle, based only on measured kinematic data. The sequence of inverse dynamics calculations differs significantly from the conventional application of inverse dynamics using force plate data. A new validated "Smooth Transition Assumption" was used to solve the indeterminacy problem in the double support phase. Kinematic data is required for all major body segments and, hence, a whole body gait measurement protocol is presented. Finally, sensitivity analyses were conducted to evaluate the effects of digital filtering and body segment parameters on the accuracy of the prediction results. The model gave reasonably good estimates of sagittal plane ground forces and moment; however, the estimates in the other planes were less good, which we believe is largely due to their small magnitudes in comparison to the sagittal forces and moment. The errors observed are most likely caused by errors in the kinematic data resulting from skin movement artefact and by errors in the estimated body segment parameters. A digital filtering cut-off frequency of 4.5 Hz was found to produce the best results. It was also shown that errors in the mass properties of body segments can play a crucial role, with changes in properties sometimes having a disproportionate effect on the calculated ground reactions. The implication of these results is that, even when force plate data is available, the estimated joint forces are likely to suffer from similar errors.

Citing Articles

Optimal control simulations tracking wearable sensor signals provide comparable running gait kinematics to marker-based motion capture.

McConnochie G, Fox A, Bellenger C, Thewlis D PeerJ. 2025; 13:e19035.

PMID: 40061227 PMC: 11890300. DOI: 10.7717/peerj.19035.


Fatigue Behavior of the Auxetic Porous Bone Screw Under the Multiaxial Cyclic Loads in Tibiotalocalcaneal Arthrodesis.

Huang H, Liu J, Yao Y, Wang L, Fan Y Ann Biomed Eng. 2025; .

PMID: 39955479 DOI: 10.1007/s10439-025-03693-3.


A wearable gait lab powered by sensor-driven digital twins for quantitative biomechanical analysis post-stroke.

Simonetti D, Hendriks M, Koopman B, Keijsers N, Sartori M Wearable Technol. 2024; 5:e13.

PMID: 39575324 PMC: 11579882. DOI: 10.1017/wtc.2024.14.


Handrim Reaction Force and Moment Assessment Using a Minimal IMU Configuration and Non-Linear Modeling Approach during Manual Wheelchair Propulsion.

Aissaoui R, De Lutiis A, Feghoul A, Chenier F Sensors (Basel). 2024; 24(19).

PMID: 39409347 PMC: 11478896. DOI: 10.3390/s24196307.


Errors in Estimating Lower-Limb Joint Angles and Moments during Walking Based on Pelvic Accelerations: Influence of Virtual Inertial Measurement Unit's Frontal Plane Misalignment.

Inai T, Kobayashi Y, Sudo M, Yamashiro Y, Ueda T Sensors (Basel). 2024; 24(16).

PMID: 39204793 PMC: 11359074. DOI: 10.3390/s24165096.