» Articles » PMID: 18663511

Echocardiography and the Neonatologist

Overview
Journal Pediatr Cardiol
Date 2008 Jul 30
PMID 18663511
Citations 20
Authors
Affiliations
Soon will be listed here.
Abstract

Pediatric echocardiography as performed and interpreted by pediatric cardiologists provides details of cardiac structure and function as well as hemodynamic data. Functional echocardiography, in contrast to echocardiography as performed by the cardiologist, is the bedside use of cardiac ultrasound to follow functional and hemodynamic changes longitudinally. Data reflecting cardiac function and systemic and pulmonary blood flow in critically ill preterm and term neonates can be monitored using this method. Functional echocardiography is being developed and driven by neonatologists as an extension of their clinical skills. A wealth of hemodynamic information can be derived from functional echocardiography used for the sick neonate, which provides clinical information different from the assumed underlying physiology. Lack of access to appropriate training programs and interdisciplinary politics is limiting the use of this potentially valuable clinical information. Without the use of functional echocardiography, clinicians are left to speculate as to the underlying pathophysiology of circulatory compromise, and the assumptions they make often are incorrect. For functional echocardiography to fulfill its clinical potential, it needs to be available at any time and at short notice in the neonatal intensive care unit (NICU). Because most NICUs do not have external diagnostic services to provide longitudinal hemodynamic follow-up assessment at the bedside, neonatologists should be able to develop appropriate echocardiographic skills in close collaboration with their cardiologist colleagues.

Citing Articles

Artificial intelligence-assisted echocardiographic monitoring in pediatric patients on extracorporeal membrane oxygenation.

Chen W, Wu J, Zhang Z, Gao Z, Chen X, Zhang Y Front Cardiovasc Med. 2024; 11:1418741.

PMID: 39723412 PMC: 11669191. DOI: 10.3389/fcvm.2024.1418741.


Evaluation of Neonatologist-Provided Echocardiography in a Tertiary NICU in the United Arab Emirates.

Raza S, Ibrahim C Cureus. 2024; 16(10):e72551.

PMID: 39606535 PMC: 11601170. DOI: 10.7759/cureus.72551.


Management Practices for Hemodynamic Impairment in Neonates Born Prematurely: A Quality Improvement Project.

Lalin O, Gaga S, Hascoet J J Clin Med. 2024; 13(22).

PMID: 39597989 PMC: 11594651. DOI: 10.3390/jcm13226848.


Growth of targeted neonatal echocardiography in Chinese neonatal intensive care units: gaps in practice and training.

Deng Y, Cao X, Mertens L, McNamara P Eur J Pediatr. 2023; 182(8):3457-3466.

PMID: 37184647 DOI: 10.1007/s00431-023-05008-x.


Neonatologist Performed Echocardiography for Evaluating the Newborn Infant.

Nestaas E Front Pediatr. 2022; 10:853205.

PMID: 35402362 PMC: 8987714. DOI: 10.3389/fped.2022.853205.


References
1.
Kluckow M, Evans N . Early echocardiographic prediction of symptomatic patent ductus arteriosus in preterm infants undergoing mechanical ventilation. J Pediatr. 1995; 127(5):774-9. DOI: 10.1016/s0022-3476(95)70172-9. View

2.
Ward C, Purdie J . Diagnostic accuracy of paediatric echocardiograms interpreted by individuals other than paediatric cardiologists. J Paediatr Child Health. 2001; 37(4):331-6. DOI: 10.1046/j.1440-1754.2001.00695.x. View

3.
Kluckow M, Seri I, Evans N . Functional echocardiography: an emerging clinical tool for the neonatologist. J Pediatr. 2007; 150(2):125-30. DOI: 10.1016/j.jpeds.2006.10.056. View

4.
Seri I . Low superior vena cava flow during the first postnatal day and neurodevelopment in preterm neonates. J Pediatr. 2004; 145(5):573-5. DOI: 10.1016/j.jpeds.2004.08.064. View

5.
Kluckow M, Evans N . Relationship between blood pressure and cardiac output in preterm infants requiring mechanical ventilation. J Pediatr. 1996; 129(4):506-12. DOI: 10.1016/s0022-3476(96)70114-2. View