Optimization of Deterministic Transport Parameters for the Calculation of the Dose Distribution Around a High Dose-rate 192Ir Brachytherapy Source

Overview
Journal Med Phys
Specialty Biophysics
Date 2008 Jul 25
PMID 18649459
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

The goal of this work was to calculate the dose distribution around a high dose-rate 192Ir brachytherapy source using a multi-group discrete ordinates code and then to compare the results with a Monte Carlo calculated dose distribution. The unstructured tetrahedral mesh discrete ordinates code Attila version 6.1.1 was used to calculate the photon kerma rate distribution in water around the Nucletron microSelectron mHDRv2 source. MCNPX 2.5.c was used to compute the Monte Carlo water photon kerma rate distribution. Two hundred million histories were simulated, resulting in standard errors of the mean of less than 3% overall. The number of energy groups, S(n) (angular order), P(n) (scattering order), and mesh elements were varied in addition to the method of analytic ray tracing to assess their effects on the deterministic solution. Water photon kerma rate matrices were exported from both codes into an in-house data analysis software. This software quantified the percent dose difference distribution, the number of points within +/- 3% and +/- 5%, and the mean percent difference between the two codes. The data demonstrated that a 5 energy-group cross-section set calculated results to within 0.5% of a 15 group cross-section set. S12 was sufficient to resolve the solution in angle. P2 expansion of the scattering cross-section was necessary to compute accurate distributions. A computational mesh with 55 064 tetrahedral elements in a 30 cm diameter phantom resolved the solution spatially. An efficiency factor of 110 with the above parameters was realized in comparison to MC methods. The Attila code provided an accurate and efficient solution of the Boltzmann transport equation for the mHDRv2 source.

Citing Articles

Linear Boltzmann equation solver for voxel-level dosimetry in radiopharmaceutical therapy: Comparison with Monte Carlo and kernel convolution.

Kayal G, Van B, Andl G, Tu C, Wareing T, Wilderman S Med Phys. 2024; 51(8):5604-5617.

PMID: 38436493 PMC: 11321934. DOI: 10.1002/mp.16996.


Dosimetric Impact of Air Pockets in the Vaginal Cuff Brachytherapy Using Model-based Dose Calculation Algorithm.

Puriparthi L, Talluri A, Akkineni N, Bajwa H, Tumu V, Sresty N J Med Phys. 2024; 48(4):373-377.

PMID: 38223798 PMC: 10783181. DOI: 10.4103/jmp.jmp_88_23.


Validation of the TOPAS Monte Carlo toolkit for HDR brachytherapy simulations.

Berumen F, Ma Y, Ramos-Mendez J, Perl J, Beaulieu L Brachytherapy. 2021; 20(4):911-921.

PMID: 33896732 PMC: 11370651. DOI: 10.1016/j.brachy.2020.12.007.


A fast, linear Boltzmann transport equation solver for computed tomography dose calculation (Acuros CTD).

Wang A, Maslowski A, Wareing T, Star-Lack J, Schmidt T Med Phys. 2018; 46(2):925-933.

PMID: 30471131 PMC: 6367051. DOI: 10.1002/mp.13305.


Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter - Part I: Core algorithms and validation.

Maslowski A, Wang A, Sun M, Wareing T, Davis I, Star-Lack J Med Phys. 2018; 45(5):1899-1913.

PMID: 29509970 PMC: 5948176. DOI: 10.1002/mp.12850.