» Articles » PMID: 18632306

The Clinical Utility of Methods to Determine Spatial Extent and Volume of Tissue Activated by Deep Brain Stimulation

Overview
Publisher Elsevier
Specialties Neurology
Psychiatry
Date 2008 Jul 18
PMID 18632306
Citations 6
Authors
Affiliations
Soon will be listed here.
Citing Articles

Neurons under genetic control: What are the next steps towards the treatment of movement disorders?.

Tsanov M Comput Struct Biotechnol J. 2020; 18:3577-3589.

PMID: 33304456 PMC: 7708864. DOI: 10.1016/j.csbj.2020.11.012.


High resolution transcranial acoustoelectric imaging of current densities from a directional deep brain stimulator.

Preston C, Alvarez A, Barragan A, Becker J, Kasoff W, Witte R J Neural Eng. 2020; 17(1):016074.

PMID: 31978914 PMC: 7446234. DOI: 10.1088/1741-2552/ab6fc3.


Selective Mapping of Deep Brain Stimulation Lead Currents Using Acoustoelectric Imaging.

Preston C, Kasoff W, Witte R Ultrasound Med Biol. 2018; 44(11):2345-2357.

PMID: 30119863 PMC: 6163075. DOI: 10.1016/j.ultrasmedbio.2018.06.021.


Probabilistic mapping of deep brain stimulation effects in essential tremor.

Dembek T, Barbe M, Astrom M, Hoevels M, Visser-Vandewalle V, Fink G Neuroimage Clin. 2016; 13:164-173.

PMID: 27981031 PMC: 5144752. DOI: 10.1016/j.nicl.2016.11.019.


Effects of Electrical Stimulation in the Inferior Colliculus on Frequency Discrimination by Rhesus Monkeys and Implications for the Auditory Midbrain Implant.

Pages D, Ross D, Punal V, Agashe S, Dweck I, Mueller J J Neurosci. 2016; 36(18):5071-83.

PMID: 27147659 PMC: 4854969. DOI: 10.1523/JNEUROSCI.3540-15.2016.


References
1.
Gross R, Krack P, Rodriguez-Oroz M, Rezai A, Benabid A . Electrophysiological mapping for the implantation of deep brain stimulators for Parkinson's disease and tremor. Mov Disord. 2006; 21 Suppl 14:S259-83. DOI: 10.1002/mds.20960. View

2.
McIntyre C, Miocinovic S, Butson C . Computational analysis of deep brain stimulation. Expert Rev Med Devices. 2007; 4(5):615-22. DOI: 10.1586/17434440.4.5.615. View

3.
Hemm S, Mennessier G, Vayssiere N, Cif L, Coubes P . Co-registration of stereotactic MRI and isofieldlines during deep brain stimulation. Brain Res Bull. 2005; 68(1-2):59-61. DOI: 10.1016/j.brainresbull.2005.08.024. View

4.
Wagenaar D, Pine J, Potter S . Effective parameters for stimulation of dissociated cultures using multi-electrode arrays. J Neurosci Methods. 2004; 138(1-2):27-37. DOI: 10.1016/j.jneumeth.2004.03.005. View

5.
Yousif N, Liu X . Modeling the current distribution across the depth electrode-brain interface in deep brain stimulation. Expert Rev Med Devices. 2007; 4(5):623-31. PMC: 2268755. DOI: 10.1586/17434440.4.5.623. View