» Articles » PMID: 18626677

Validity of Accelerometry in Assessing the Duration of the Sit-to-stand Movement

Overview
Publisher Springer
Date 2008 Jul 16
PMID 18626677
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

Accelerometry is frequently used in movement analysis to assess body postures and motions. Here, we assessed the validity of ambulatory accelerometric measurement of the sit-to-stand (STS) movement duration. We compared accelerometric and opto-electronic assessment of the STS movement duration under four conditions (comfortable, slow, fast movement and exaggerated trunk flexion) with six healthy subjects and six subjects with stroke who performed movements six times under each condition. Accelerometric and opto-electronic data of STS movement duration were strongly related (r = 0.98). Accelerometry showed a fixed bias of 0.07 s (95% CI 0.008, 0.141) in healthy subjects and 0.32 s (95% CI 0.223, 0.422) in stroke subjects. In healthy subjects, a significant negative proportional bias of 0.1 was detected (95% CI -0.160, -0.032). Accelerometry showed discriminative validity in comparing stroke subjects to healthy subjects, and in comparing speed conditions. Our results indicate that accelerometry can provide valid data on the STS movement duration, furthermore during its use additional information on the STS movement, such as balance control, can be recorded.

Citing Articles

Estimating balance, cognitive function, and falls risk using wearable sensors and the sit-to-stand test.

Greene B, Doheny E, McManus K, Caulfield B Wearable Technol. 2024; 3:e9.

PMID: 38486905 PMC: 10936403. DOI: 10.1017/wtc.2022.6.


The relationship between acceleration in sit-to-stand and falls in community-dwelling older adults: cross-sectional study.

Tateoka K, Tsuji T, Shoji T, Tokunaga S, Okura T J Phys Ther Sci. 2024; 36(2):74-80.

PMID: 38304148 PMC: 10830154. DOI: 10.1589/jpts.36.74.


Relationship between Acceleration in a Sit-To-Stand Movement and Physical Function in Older Adults.

Tateoka K, Tsuji T, Shoji T, Tokunaga S, Okura T Geriatrics (Basel). 2023; 8(6).

PMID: 38132494 PMC: 10742784. DOI: 10.3390/geriatrics8060123.


Temporal, Kinematic and Kinetic Variables Derived from a Wearable 3D Inertial Sensor to Estimate Muscle Power during the 5 Sit to Stand Test in Older Individuals: A Validation Study.

Bochicchio G, Ferrari L, Bottari A, Lucertini F, Scarton A, Pogliaghi S Sensors (Basel). 2023; 23(10).

PMID: 37430715 PMC: 10220531. DOI: 10.3390/s23104802.


Reliability of Wearable Sensors for Assessing Gait and Chair Stand Function at Home in People With Knee Osteoarthritis.

Rose M, Neogi T, Friscia B, Torabian K, LaValley M, Gheller M Arthritis Care Res (Hoboken). 2023; 75(9):1939-1948.

PMID: 36734316 PMC: 10397366. DOI: 10.1002/acr.25096.


References
1.
Bussmann J, Tulen J, van Herel E, Stam H . Quantification of physical activities by means of ambulatory accelerometry: a validation study. Psychophysiology. 1998; 35(5):488-96. DOI: 10.1017/s0048577298971153. View

2.
Podsiadlo D, Richardson S . The timed "Up & Go": a test of basic functional mobility for frail elderly persons. J Am Geriatr Soc. 1991; 39(2):142-8. DOI: 10.1111/j.1532-5415.1991.tb01616.x. View

3.
Bussmann J, van de Laar Y, Neeleman M, Stam H . Ambulatory accelerometry to quantify motor behaviour in patients after failed back surgery: a validation study. Pain. 1998; 74(2-3):153-61. DOI: 10.1016/s0304-3959(97)00161-9. View

4.
Janssen W, Bussmann J, Horemans H, Stam H . Analysis and decomposition of accelerometric signals of trunk and thigh obtained during the sit-to-stand movement. Med Biol Eng Comput. 2005; 43(2):265-72. DOI: 10.1007/BF02345965. View

5.
Jones C, Rikli R, Beam W . A 30-s chair-stand test as a measure of lower body strength in community-residing older adults. Res Q Exerc Sport. 1999; 70(2):113-9. DOI: 10.1080/02701367.1999.10608028. View