Abstract

The present study sought to establish a standard in vivo imaging procedure for mouse kidney anatomy evaluation using contrast-enhanced high-resolution X-ray microtomography (micro-CT). Micro-CT estimation of kidney volume was compared with ex vivo measurement by micro-CT and water displacement. Control values were obtained in four strains (BALB/c, C3H/HeN, 129/Sv and C57BL/6J) of healthy male and female mice aged 22 +/- 2 weeks. An excellent correlation was found between in vivo and ex vivo kidney volumes (n = 26 mice; 52 kidneys; r = 0.96). In vivo measurement systematically overestimated ex vivo kidney volume by 28 +/- 4%, while there was no significant difference between the ex vivo micro-CT value and the true kidney volume on water displacement (2.3 +/- 2.1%). In vivo kidney volume also correlated strongly with kidney weight and in vivo kidney length (n = 52 mice; 104 kidneys; r = 0.84, r = 0.92 respectively). Differences between strains were observed for kidney volume when comparing either kidney volume or kidney weight to body weight. In conclusion, this study demonstrated that contrast-enhanced micro-CT enables accurate in vivo measurement of kidney volume, length and thickness in mice. Reference parameters are reported for four strains. The technique provides a useful follow-up research tool for mouse phenotyping and renal disease studies.

Citing Articles

Caloric restriction reduces proteinuria in male rats with established nephropathy.

Sijbesma J, van Waarde A, Klooster A, Kion I, Slart R, Lammertsma A Physiol Rep. 2024; 12(5):e15942.

PMID: 38439743 PMC: 10912948. DOI: 10.14814/phy2.15942.


Cryogenic contrast-enhanced microCT enables nondestructive 3D quantitative histopathology of soft biological tissues.

Maes A, Pestiaux C, Marino A, Balcaen T, Leyssens L, Vangrunderbeeck S Nat Commun. 2022; 13(1):6207.

PMID: 36266273 PMC: 9584947. DOI: 10.1038/s41467-022-34048-4.


Automated total kidney volume measurements in pre-clinical magnetic resonance imaging for resourcing imaging data, annotations, and source code.

Edwards M, Periyanan S, Anaam D, Gregory A, Kline T Kidney Int. 2020; 99(3):763-766.

PMID: 32828755 PMC: 7895853. DOI: 10.1016/j.kint.2020.07.040.


Optimizing imaging of the rat pulmonary microvasculature by micro-computed tomography.

Deng Y, Rowe K, Chaudhary K, Yang A, Mei S, Stewart D Pulm Circ. 2019; 9(4):2045894019883613.

PMID: 31700608 PMC: 6823983. DOI: 10.1177/2045894019883613.


Effects of concurrent chloroquine and ethanol administration on the rat kidney morphology.

Abdulkadir A, Mbajiorgu E, Nyirenda T Pan Afr Med J. 2018; 29:49.

PMID: 30402202 PMC: 6211805. DOI: 10.11604/pamj.2018.29.49.12471.