Monitoring of Influenza Virus Hemagglutinin in Process Samples Using Weak Affinity Ligands and Surface Plasmon Resonance
Overview
Authors
Affiliations
Surface plasmon resonance (SPR) was used to screen the interaction between a variety of affinity ligands and hemagglutinin (HA) from human influenza virus, with the aim of identifying low affinity ligands useful for the development of a rapid bioanalytical sensor. Three sialic acid-based structures and four lectins were evaluated as sensor ligands. The sialic acid-based ligands included a natural sialic acid-containing glycoprotein, human alpha1-acid glycoprotein (alpha1-AGP), and two synthetic 6'-sialyllactose-conjugates, with varying degree of substitution. The interaction of HA with the four lectin-based ligands, concanavalin A (Con A), wheat germ agglutinin (WGA), Maackia amurensis lectin (MAL), and Sambucus nigra agglutinin (SNA), showed a wide variation of affinity strengths. Affinity and kinetics data were estimated. Strong affinities were observed for Con A, WGA, alpha1-AGP, and a 6'-sialyllactose-conjugate with a high substitution degree, and low affinities were observed for MAL and a 6'-sialyllactose-conjugate with low substitution. The main objective, to identify a low affinity ligand which could be used for on-line monitoring and product quantification, was met by a 6'-sialyllactose-ovalbumin conjugate that had 0.6 mol ligand per mol carrier protein. The apparent affinity of this ligand was estimated to be 1.5+/-0.03 microM (K(D)) on the SPR surface. Vaccine process samples containing HA were analyzed in the range 10-100 microg HA mL(-1) and correlated with single-radial immunodiffusion. The coefficient of variation on the same chip was between 0.010 and 0.091.
Antibody-independent surface plasmon resonance assays for influenza vaccine quality control.
Serafin B, Kamen A, De Crescenzo G, Henry O Appl Microbiol Biotechnol. 2024; 108(1):307.
PMID: 38656587 PMC: 11043112. DOI: 10.1007/s00253-024-13145-y.
Khalenkov A, Norton M, Scott D Heliyon. 2023; 9(5):e15651.
PMID: 37144181 PMC: 10151358. DOI: 10.1016/j.heliyon.2023.e15651.
Ultrasensitive and Regenerative Transistor Sensor Based on Dynamic Covalent Chemistry.
Cao B, Dai C, Wang X, Xiao Q, Wei D Sensors (Basel). 2022; 22(18).
PMID: 36146305 PMC: 9505547. DOI: 10.3390/s22186947.
Kim Y, Sagara K, Uezu K Polymers (Basel). 2022; 14(4).
PMID: 35215575 PMC: 8880166. DOI: 10.3390/polym14040663.
Recent Advances in AIV Biosensors Composed of Nanobio Hybrid Material.
Lee T, Ahn J, Park S, Kim G, Kim J, Kim T Micromachines (Basel). 2018; 9(12).
PMID: 30544883 PMC: 6316213. DOI: 10.3390/mi9120651.