» Articles » PMID: 18591596

Does the Joint Line Matter in Revision Total Knee Replacement?

Overview
Date 2008 Jul 2
PMID 18591596
Citations 41
Authors
Affiliations
Soon will be listed here.
Abstract

We identified 148 patients who had undergone a revision total knee replacement using a single implant system between 1990 and 2000. Of these 18 patients had died, six had developed a peri-prosthetic fracture and ten had incomplete records or radiographs. This left 114 with prospectively-collected radiographs and Bristol knee scores available for study. The height of the joint line before and after revision total knee replacement was measured and classified as either restored to within 5 mm of the pre-operative height or elevated if it was positioned more than 5 mm above the pre-operative height. The joint line was elevated in 41 knees (36%) and restored in 73 (64%). Revision surgery significantly improved the mean Bristol knee score from 41.1 (SD 15.9) pre-operatively to 80.5 (SD 15) post-operatively (p < 0.001). At one year post-operatively both the total Bristol knee score and its functional component were significantly better in the restored group than in the elevated group (p < 0.01). Overall, revision from a unicondylar knee replacement required less use of bone graft, fewer component augments, restored the joint line more often and gave a significantly better total Bristol knee score (p < 0.02) and functional score (p < 0.01) than revision from total knee replacement. Our findings show that restoration of the joint line at revision total knee replacement gives a significantly better result than leaving it unrestored by more than 5 mm. We recommend the greater use of distal femoral augments to help to achieve this goal.

Citing Articles

Methicillin-resistant Staphylococcus epidermidis knee prosthetic infection treatment with two-stage revision and fosfomycin-rifampin combination therapy: a case report.

Marcheggiani Muccioli G, Zamparini E, Fogacci A, Grechi A, Pea F, Viale P J Med Case Rep. 2025; 19(1):55.

PMID: 39924484 PMC: 11808996. DOI: 10.1186/s13256-025-05073-w.


Clinical Study and Finite Element Analysis on the Effects of Pseudo-Patella Baja After TKA.

Jiang S, Wei W, Li M, Zhou S, Zeng Y, Shen B Orthop Surg. 2024; 17(1):212-223.

PMID: 39575599 PMC: 11735365. DOI: 10.1111/os.14289.


Does Patellar Height Influence Range of Motion and Anterior Knee Pain after Distal Femur Endoprosthesis Reconstruction?.

Sambri A, Paganelli C, Parisi S, Filippini M, Cevolani L, Stimolo D J Clin Med. 2024; 13(14).

PMID: 39064234 PMC: 11277792. DOI: 10.3390/jcm13144194.


Prediction of Distal Femoral and Posterior Articular Surfaces in Total Knee Arthroplasty With Severe Bone Defects Using Computed Tomography-Based Templating Software.

Hirakawa M, Miyazaki M, Sato M, Kaku N Cureus. 2024; 16(6):e61546.

PMID: 38962584 PMC: 11219248. DOI: 10.7759/cureus.61546.


A comparison of joint line height after revision total knee replacement using a rotating hinge versus a condylar revision knee system.

Watts D, Kendoff D, Sussmann P, Klauser W, Heinert G J Clin Orthop Trauma. 2024; 47:102315.

PMID: 38196496 PMC: 10772370. DOI: 10.1016/j.jcot.2023.102315.