» Articles » PMID: 18562723

64-MDCT Coronary Angiography: Phantom Study of Effects of Vascular Attenuation on Detection of Coronary Stenosis

Overview
Specialties Oncology
Radiology
Date 2008 Jun 20
PMID 18562723
Citations 40
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: The purpose of this study was to investigate the effects of vascular attenuation on the accuracy of stenosis evaluation with 64-MDCT coronary angiography.

Materials And Methods: A pulsating cardiac phantom was used to simulate the beating heart and coronary arteries of 5 and 3 mm in diameter with three degrees of stenosis (25%, 50%, and 75%) at a heart rate of 55 beats per minute. Coronary vascular enhancement had four attenuation levels: low, 200 H; moderately low, 300 H; moderately high, 350 H; and high, 500 H. Cardiac scans were obtained with 64-MDCT. Percentage stenosis, plaque area, and plaque density were measured on axial images.

Results: For 50% and 75% stenosis in 5-mm vessels, there were no significant differences among the four attenuation groups. For 50% and 75% stenosis in 3-mm vessels, significant underestimation of percentage stenosis occurred in the high-attenuation group compared with the moderate- and low-attenuation groups (p < 0.05). For 25% stenosis in 5-mm vessels, low attenuation led to significant overestimation of degree of stenosis compared with the moderate and high attenuation levels (p < 0.05). None of the instances of 25% stenosis in 3-mm vessels were detected in the high-attenuation group. Underestimation was found only for 3-mm vessels. For 75% stenosis, all plaques were detected irrespective of contrast attenuation and vessel size.

Conclusion: Use of higher attenuation leads to a significant underestimation of stenosis in smaller vessels. Lower attenuation leads to slight and clinically acceptable overestimation of stenosis. The optimal vascular attenuation for stenosis detection in coronary 64-MDCT angiography is approximately 350 H.

Citing Articles

Reduced contrast agent volume using a heart-rate dependent and free-breathing scanning protocol in coronary computed tomography angiography (CTA) for patients with chronic obstructive pulmonary disease (COPD).

Wang Z, Chen G, Song D, Xu X, Chu C, Zhang S BMC Cardiovasc Disord. 2025; 25(1):15.

PMID: 39794706 PMC: 11721589. DOI: 10.1186/s12872-024-04437-2.


Anatomic association between the gastrocolic trunk of Henle and right colic artery by high-quality CT venography.

Zhao X, Zhang H, Zhao H, Kong D, Zeng W, Gao F Sci Rep. 2024; 14(1):32054.

PMID: 39738458 PMC: 11685880. DOI: 10.1038/s41598-024-83588-w.


Halved contrast medium dose coronary dual-layer CT-angiography - phantom study of tube current and patient characteristics.

Kristiansen C, Tetteroo P, Dobrolinska M, Lauritzen P, Velthuis B, Greuter M Int J Cardiovasc Imaging. 2024; 40(4):931-940.

PMID: 38386192 PMC: 11052773. DOI: 10.1007/s10554-024-03062-6.


Halved contrast medium dose in lower limb dual-energy computed tomography angiography-a randomized controlled trial.

Kristiansen C, Thomas O, Tran T, Roy S, Hykkerud D, Sanderud A Eur Radiol. 2023; 33(9):6033-6044.

PMID: 37071166 PMC: 10415441. DOI: 10.1007/s00330-023-09575-3.


A patient- and acquisition-tailored injection approach for improving consistency of CT enhancement towards a target CT value in coronary CT angiography.

Van Gompel G, Delombaerde L, Zanca F, Tanaka K, Belsack D, De Mey J J Appl Clin Med Phys. 2022; 24(1):e13867.

PMID: 36537145 PMC: 9860000. DOI: 10.1002/acm2.13867.