» Articles » PMID: 18534384

Minimum Ten-year Results of a Porous Acetabular Component for Crowe I to III Hip Dysplasia Using an Elevated Hip Center

Overview
Journal J Arthroplasty
Specialty Orthopedics
Date 2008 Jun 7
PMID 18534384
Citations 29
Authors
Affiliations
Soon will be listed here.
Abstract

We conducted a retrospective study of the placement of porous-coated acetabular components using screws at more than 20 mm above the teardrop without structural bone graft for dysplastic hips to determine long-term outcome. Thirty hips (29 patients) were monitored for a mean of 15.2 years (range, 10.4-18.3 years) after surgery. Compared with 12 contralateral normal hips, the distance of the hip center from the teardrop was significantly high (26.8 +/- 4.8 and 13.4 +/- 2.7 mm P < .001); however, it was not laterally different (31. 5 +/- 5.1 and 31.7 +/- 5.0 mm). No acetabular components showed loosening. One metal shell was revised for wear and osteolysis. Morselized bone grafted in 25 hips was incorporated in all cases. Slight elevation of the hip center without lateralization in cementless cups fixed with screws was well tolerated for dysplastic hips.

Citing Articles

Midterm Results of Severe Hip Dysplasia after Using a Cementless Acetabular Component with Bulk Bone Graft in Total Hip Arthroplasty: A Minimum Five-Year Follow-Up Study.

Konno T, Shimizu T, Inoue M, Masuda T, Terkawi M, Iwasaki N Bioengineering (Basel). 2024; 11(8).

PMID: 39199799 PMC: 11351995. DOI: 10.3390/bioengineering11080841.


Total Hip Arthroplasty With Subtrochanteric Osteotomy for Crowe IV Dysplasia Using an Extensile Direct Anterior Approach: A Surgical Technique.

Muffly B, Hegeman E, Hartline B, Singh K, Premkumar A, Guild 3rd G Arthroplast Today. 2024; 27:101374.

PMID: 39071821 PMC: 11282430. DOI: 10.1016/j.artd.2024.101374.


The press-fit technique without screws and bone graft can be used as an alternative method in Crowe type II and III hip dysplasia.

Cataltepe A, Iyetin Y Turk J Med Sci. 2024; 53(5):1448-1457.

PMID: 38813005 PMC: 10763771. DOI: 10.55730/1300-0144.5712.


Cup Overhanging in Anatomic Socket Position or High Hip Center of Rotation in Total Hip Arthroplasty for Crowe III and IV Dysplasia: A CT-Based Simulation.

Castagnini F, Giardina F, Fustini C, Tassinari E, Bordini B, Cosentino M J Clin Med. 2023; 12(2).

PMID: 36675535 PMC: 9862580. DOI: 10.3390/jcm12020606.


Meta-analysis of the Efficacy of the Anatomical Center and High Hip Center Techniques in the Treatment of Adult Developmental Dysplasia of the Hip.

Wu C, Shu G, Xie X, Yuan X, Chen S Biomed Res Int. 2022; 2022:7256664.

PMID: 36082152 PMC: 9448599. DOI: 10.1155/2022/7256664.