Biodegradation of Inion Fast-absorbing Biodegradable Plates and Screws

Overview
Date 2008 Jun 4
PMID 18520394
Citations 15
Authors
Affiliations
Soon will be listed here.
Abstract

Biodegradable plates and screws are recommended for use in surgery of the craniofacial skeleton of children. To be effective and not interfere with growth of the child's skull, the plates must biodegrade sufficiently to release the holding power of the plate and screw within 1 year. It is also essential that excessive foreign body reaction and cyst formation does not occur when the plates and screws biodegrade. The purpose of this experimental study was to evaluate the rate of biodegradation of Inion CPS Baby biodegradable plates and screws under different clinical circumstances in the rabbit craniofacial skeleton and evaluate their efficacy for use in pediatric craniofacial surgery. Foreign body reaction would be evaluated. Inion baby plates and screws were tested in a rabbit model. Plates were applied to the frontal bone, over a bony defect of the parietal bone, to a nasal bone fracture, and inserted in the subcutaneous space over the occipital bone in thirty 6-week-old rabbits. Six rabbits were euthanized at 9, 12, 15, and 18 months' postoperative time point and examined for residual plates and screws. Bone from each surgical site was excised, fixed by immersion in 10% neutral-buffered formalin, decalcified in Immunocal solution, and examined by 7-microm paraffin sections stained with hematoxylin and eosin. At 9 months, the plates and screws had effectively biodegraded and no longer had holding power on the bones. Fragmentation of the implant material was noted. Residual implant material was still present on gross and histologic examination in rabbits at 9, 12, 15, and 18 months. Residue of a screw was still palpable in 1 rabbit at 18 months. There was no evidence of cyst formation in any of the examined specimens. Macrophages and giant cells were present in most of the specimens at 9, 12, 15, and 18 months. Findings from the current study revealed a relative short resorption time (9 mo) and normal inflammatory sequelae in an adult rabbit model. These findings suggest that these plates may be used safely in fixing the pediatric craniofacial skeleton.

Citing Articles

Are Absorbable Plates More Resistant to Infection Than Titanium Implants? An Experimental Pre-Clinical Trial in Rabbits.

Kitridis D, Savvidis P, Cheva A, Papalois A, Givissis P, Chalidis B J Funct Biomater. 2023; 14(10).

PMID: 37888163 PMC: 10607271. DOI: 10.3390/jfb14100498.


Titanium or Biodegradable Osteosynthesis in Maxillofacial Surgery? In Vitro and In Vivo Performances.

Gareb B, van Bakelen N, Vissink A, Bos R, van Minnen B Polymers (Basel). 2022; 14(14).

PMID: 35890557 PMC: 9316877. DOI: 10.3390/polym14142782.


Biocompatibility and degradation comparisons of four biodegradable copolymeric osteosynthesis systems used in maxillofacial surgery: A goat model with four years follow-up.

Gareb B, van Bakelen N, Driessen L, Buma P, Kuipers J, Grijpma D Bioact Mater. 2022; 17:439-456.

PMID: 35386449 PMC: 8961280. DOI: 10.1016/j.bioactmat.2022.01.015.


Αbsorbable Plates for Isolated Ulnar Diaphyseal Fractures in Adults - A Case Series Study.

Kapoutsis D, Kitridis D, Sachinis N, Ploumis A, Givissis P J Orthop Case Rep. 2021; 10(4):49-53.

PMID: 33623767 PMC: 7885649. DOI: 10.13107/jocr.2020.v10.i04.1798.


Clinical courses and degradation patterns of absorbable plates in facial bone fracture patients.

Kim Y, Lee J Arch Craniofac Surg. 2019; 20(5):297-303.

PMID: 31658793 PMC: 6822079. DOI: 10.7181/acfs.2019.00409.