» Articles » PMID: 18502995

Detection of Corneal Fibrosis by Imaging Second Harmonic-generated Signals in Rabbit Corneas Treated with Mitomycin C After Excimer Laser Surface Ablation

Overview
Specialty Ophthalmology
Date 2008 May 27
PMID 18502995
Citations 15
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: Recent studies have shown that confocal imaging of second harmonic-generated (SHG) signals can detect corneal collagen organization. The purpose of this study was to assess whether SHG signals can detect differences in corneal fibrosis after excimer laser surface ablation (photorefractive keratectomy [PRK]).

Methods: Rabbits received 9-D PRK in one eye followed by treatment with either mitomycin C (MMC) or vehicle. Corneal haze was measured by in vivo confocal microscopy before and 2, 4, 8, and 12 weeks after surgery. Animals were then killed and corneas were evaluated by visible and nonlinear confocal microscopy.

Results: PRK induced significant haze in vehicle-treated corneas that peaked at 2 weeks and remained elevated at 12 weeks after surgery. MMC treatment significantly (P < 0.05) reduced corneal haze at 2 weeks and was essentially normal by 12 weeks. Imaging of SHG signals in vehicle-treated eyes showed an anterior layer of collagen forming a honeycomb network blending into a dense mat of irregularly arranged collagen fibers that overlaid normal orthogonally arranged collagen lamellae. MMC treatment showed normal collagen organization at the surface. Fibrotic tissue was associated with a high cell density and alignment of intracellular actin filaments with collagen fiber bundles. In MMC-treated eyes, an anterior acellular zone overlaid a sparsely populated stroma containing isolated and enlarged keratocytes.

Conclusions: Imaging of SHG signals provides a sensitive means for detection of corneal fibrosis after surface ablation and can be used to assess the effects of antifibrotic therapy on corneal healing after refractive surgery.

Citing Articles

The impact of UV cross-linking on corneal stromal cell migration, differentiation and patterning.

Petroll W, Miron-Mendoza M, Sunkara Y, Ikebe H, Sripathi N, Hassaniardekani H Exp Eye Res. 2023; 233:109523.

PMID: 37271309 PMC: 10825899. DOI: 10.1016/j.exer.2023.109523.


Creation and grading of experimental corneal scars in mice models.

Cogswell D, Sun M, Greenberg E, Margo C, Espana E Ocul Surf. 2020; 19:53-62.

PMID: 33259950 PMC: 8259783. DOI: 10.1016/j.jtos.2020.11.008.


Keratocyte mechanobiology.

Petroll W, Varner V, Schmidtke D Exp Eye Res. 2020; 200:108228.

PMID: 32919993 PMC: 7655662. DOI: 10.1016/j.exer.2020.108228.


Composition, structure and function of the corneal stroma.

Espana E, Birk D Exp Eye Res. 2020; 198:108137.

PMID: 32663498 PMC: 7508887. DOI: 10.1016/j.exer.2020.108137.


Quantitative Discrimination of Healthy and Diseased Corneas With Second Harmonic Generation Microscopy.

Avila F, Artal P, Bueno J Transl Vis Sci Technol. 2019; 8(3):51.

PMID: 31293806 PMC: 6601709. DOI: 10.1167/tvst.8.3.51.


References
1.
Lai Y, Wang H, Lin C, Chang S . Mitomycin C alters corneal stromal wound healing and corneal haze in rabbits after argon-fluoride excimer laser photorefractive keratectomy. J Ocul Pharmacol Ther. 2004; 20(2):129-38. DOI: 10.1089/108076804773710803. View

2.
Han M, Zickler L, Giese G, Walter M, Loesel F, Bille J . Second-harmonic imaging of cornea after intrastromal femtosecond laser ablation. J Biomed Opt. 2004; 9(4):760-6. DOI: 10.1117/1.1756919. View

3.
Mohler W, Millard A, Campagnola P . Second harmonic generation imaging of endogenous structural proteins. Methods. 2003; 29(1):97-109. DOI: 10.1016/s1046-2023(02)00292-x. View

4.
Steinert R, Ignacio T, Sarayba M . "Top hat"-shaped penetrating keratoplasty using the femtosecond laser. Am J Ophthalmol. 2007; 143(4):689-91. DOI: 10.1016/j.ajo.2006.11.043. View

5.
Stoller P, Kim B, Rubenchik A, Reiser K, Da Silva L . Polarization-dependent optical second-harmonic imaging of a rat-tail tendon. J Biomed Opt. 2002; 7(2):205-14. DOI: 10.1117/1.1431967. View