Combinations of Techniques in Imaging the Retina with High Resolution

Overview
Specialty Ophthalmology
Date 2008 May 23
PMID 18495519
Citations 36
Authors
Affiliations
Soon will be listed here.
Abstract

Developments in optical coherence tomography (OCT) have expanded its clinical applications for high-resolution imaging of the retina, as a standalone diagnostic and in combination with other optical imaging modalities. This review presents currently explored combinations of OCT technology with a variety of complementary imaging modalities along with augmentational technologies such as adaptive optics (AO) and tracking. Some emphasis is on the combination of OCT technology with scanning laser ophthalmoscopy (SLO) as well as on using OCT to produce an SLO-like image. Different OCT modalities such as time domain and spectral domain are discussed in terms of their performance and suitability for imaging the retina. Each modality admits several implementations, such as flying spot or using an area or line illumination. Flying spot has taken two principle forms, en-face and longitudinal OCT. The review presents the advantages and disadvantages of different possible combinations of OCT and SLO with AO, evaluating criteria in choosing the best OCT method to fit a specific combination of techniques. Some of these combinations of techniques evolved from bench systems into the clinic, their merit can be judged on images showing different pathologies of the retina. Other potential combinations of techniques are still in their infancy, in which case the discussion will be limited to their technical principles. The potential of any combined implementation to provide clinical relevant data is described by three parameters, which take into account the number of voxels acquired in unit time, the minimum time required to produce or infer an en-face OCT image (or an SLO-like image) and the number of different types of information provided. The current clinically used technologies as well as those under research are comparatively evaluated based on these three parameters. As the technology has matured over the years, their evolution is discussed as well with their potential for further improvements.

Citing Articles

Scanning laser ophthalmoscopy retroillumination: applications and illusions.

Mainster M, Desmettre T, Querques G, Turner P, Ledesma-Gil G Int J Retina Vitreous. 2022; 8(1):71.

PMID: 36180893 PMC: 9524008. DOI: 10.1186/s40942-022-00421-0.


Endodontic fillings evaluated using en face OCT, microCT and SEM.

Togoe M, Craciunescu E, Topala F, Sinescu C, Nica L, Ionita C Rom J Morphol Embryol. 2022; 62(3):793-800.

PMID: 35263408 PMC: 9019634. DOI: 10.47162/RJME.62.3.17.


Assessment of the outer retina and choroid in white matter lesions participants using swept-source optical coherence tomography.

Kwapong W, Gao Y, Yan Y, Zhang Y, Zhang M, Wu B Brain Behav. 2021; 11(8):e2240.

PMID: 34291589 PMC: 8413737. DOI: 10.1002/brb3.2240.


Noninvasive Imaging Methods to Improve the Diagnosis of Oral Carcinoma and Its Precursors: State of the Art and Proposal of a Three-Step Diagnostic Process.

Romano A, Di Stasio D, Petruzzi M, Fiori F, Lajolo C, Santarelli A Cancers (Basel). 2021; 13(12).

PMID: 34201237 PMC: 8228647. DOI: 10.3390/cancers13122864.


Foveal Therapy in Blue Cone Monochromacy: Predictions of Visual Potential From Artificial Intelligence.

Sumaroka A, Cideciyan A, Sheplock R, Wu V, Kohl S, Wissinger B Front Neurosci. 2020; 14:800.

PMID: 32848570 PMC: 7416698. DOI: 10.3389/fnins.2020.00800.