» Articles » PMID: 18469085

Representation of Collective Electrical Behavior of Cardiac Cell Sheets

Overview
Journal Biophys J
Publisher Cell Press
Specialty Biophysics
Date 2008 May 13
PMID 18469085
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

The electrocardiogram (ECG) is a measure of the collective electrical behavior of the heart based on body surface measurements. With computational models or tissue preparations, various methods have been used to compute the pseudo-ECG (pECG) of bipolar and unipolar leads that can be given clinical interpretation. When spatial maps of transmembrane potential (V(m)) are available, pECG can be derived from a weighted sum of the spatial gradients of V(m). The concept of a lead field can be used to define sensitivity curves for different bipolar and unipolar leads and to determine an effective operating height for the bipolar lead position for a two-dimensional sheet of heart cells. The pseudo-vectorcardiogram (pVCG) is computed from orthogonal bipolar lead voltages, which are derived in this study from optical voltage maps of cultured monolayers of cardiac cells. Rate and propagation direction for paced activity, rotation frequency for reentrant activity, direction of the common pathway for figure-eight reentry, and transitions from paced activity to reentry can all be distinguished using the pVCG. In contrast, the unipolar pECG does not clearly distinguish among many of the different types of electrical activity. We also show that pECG can be rapidly computed by two geometrically weighted sums of V(m), one that is summed over the area of the cell sheet and the other over the perimeter of the cell sheet. Our results are compared with those of an ad hoc difference method used in the past that consists of a simple difference of the sum of transmembrane potentials on one side of a tissue sheet and that of the other.

Citing Articles

Chaotic tip trajectories of a single spiral wave in the presence of heterogeneities.

Lombardo D, Rappel W Phys Rev E. 2019; 99(6-1):062409.

PMID: 31330597 PMC: 7296979. DOI: 10.1103/PhysRevE.99.062409.


Modeling hypothermia induced effects for the heterogeneous ventricular tissue from cellular level to the impact on the ECG.

Kienast R, Handler M, Stoger M, Baumgarten D, Hanser F, Baumgartner C PLoS One. 2017; 12(8):e0182979.

PMID: 28813535 PMC: 5558962. DOI: 10.1371/journal.pone.0182979.


Spatial reproducibility of complex fractionated atrial electrogram depending on the direction and configuration of bipolar electrodes: an in-silico modeling study.

Song J, Lee Y, Hwang M, Lee J, Li C, Joung B Korean J Physiol Pharmacol. 2016; 20(5):507-14.

PMID: 27610037 PMC: 5014997. DOI: 10.4196/kjpp.2016.20.5.507.


Electrophysiological Rotor Ablation in In-Silico Modeling of Atrial Fibrillation: Comparisons with Dominant Frequency, Shannon Entropy, and Phase Singularity.

Hwang M, Song J, Lee Y, Li C, Shim E, Pak H PLoS One. 2016; 11(2):e0149695.

PMID: 26909492 PMC: 4766081. DOI: 10.1371/journal.pone.0149695.


Membrane capacitive memory alters spiking in neurons described by the fractional-order Hodgkin-Huxley model.

Weinberg S PLoS One. 2015; 10(5):e0126629.

PMID: 25970534 PMC: 4430543. DOI: 10.1371/journal.pone.0126629.


References
1.
Tung L, Cysyk J . Imaging fibrillation/defibrillation in a dish. J Electrocardiol. 2007; 40(6 Suppl):S62-5. PMC: 2154349. DOI: 10.1016/j.jelectrocard.2007.06.018. View

2.
Entcheva E, Bien H . Macroscopic optical mapping of excitation in cardiac cell networks with ultra-high spatiotemporal resolution. Prog Biophys Mol Biol. 2005; 92(2):232-57. DOI: 10.1016/j.pbiomolbio.2005.10.003. View

3.
Iravanian S, Nabutovsky Y, Kong C, Saha S, Bursac N, Tung L . Functional reentry in cultured monolayers of neonatal rat cardiac cells. Am J Physiol Heart Circ Physiol. 2003; 285(1):H449-56. DOI: 10.1152/ajpheart.00896.2002. View

4.
Gray R, Jalife J, Panfilov A, Baxter W, Cabo C, Davidenko J . Nonstationary vortexlike reentrant activity as a mechanism of polymorphic ventricular tachycardia in the isolated rabbit heart. Circulation. 1995; 91(9):2454-69. DOI: 10.1161/01.cir.91.9.2454. View

5.
Roth B . Electrical conductivity values used with the bidomain model of cardiac tissue. IEEE Trans Biomed Eng. 1997; 44(4):326-8. DOI: 10.1109/10.563303. View