» Articles » PMID: 18465817

Factorial Design Optimization and in Vivo Feasibility of Poly(epsilon-caprolactone)-micro- and Nanofiber-based Small Diameter Vascular Grafts

Overview
Date 2008 May 10
PMID 18465817
Citations 36
Authors
Affiliations
Soon will be listed here.
Abstract

Because of the severe increase of mortality by cardiovascular diseases, there has been rising interest among the tissue-engineering community for small-sized blood vessel substitutes. Here we present small diameter vascular grafts made of slow degradable poly(epsilon-caprolactone) nanofibers obtained by electrospinning. The process was optimized by a factorial design approach that led to reproducible grafts with inner diameters of 2 and 4 mm, respectively. Fiber sizes, graft morphology, and the resulting tensile stress and tensile strain values were studied as a function of various parameters in order to obtain optimal vascular grafts for implantation after gamma-sterilization. The influence of polymer concentration, solvent, needle-collector distance, applied voltage, flow rate, and spinning time has been studied. Consequently, an optimized vascular graft was implanted as an abdominal aortic substitute in nine rats for a feasibility study. Results are given following up a 12-week implantation period showing good patency, endothelization, and cell ingrowth.

Citing Articles

Manufacturing and validation of small-diameter vascular grafts: A mini review.

Hernandez-Sanchez D, Comtois-Bona M, Munoz M, Ruel M, Suuronen E, Alarcon E iScience. 2024; 27(6):109845.

PMID: 38799581 PMC: 11126982. DOI: 10.1016/j.isci.2024.109845.


Flexible, Suturable, and Leak-free Scaffolds for Vascular Tissue Engineering Using Melt Spinning.

Fernandez-Perez J, van Kampen K, Mota C, Baker M, Moroni L ACS Biomater Sci Eng. 2023; 9(8):5006-5014.

PMID: 37490420 PMC: 10428091. DOI: 10.1021/acsbiomaterials.3c00535.


Peritoneal pre-conditioning impacts long-term vascular graft patency and remodeling.

Sameti M, Shojaee M, Saleh B, Moore L, Bashur C Biomater Adv. 2023; 148:213386.

PMID: 36948108 PMC: 11459558. DOI: 10.1016/j.bioadv.2023.213386.


An Assessment of Blood Vessel Remodeling of Nanofibrous Poly(ε-Caprolactone) Vascular Grafts in a Rat Animal Model.

Horakova J, Blassova T, Tonar Z, McCarthy C, Strnadova K, Lukas D J Funct Biomater. 2023; 14(2).

PMID: 36826887 PMC: 9965469. DOI: 10.3390/jfb14020088.


Surface Coating of Polyurethane Films with Gelatin, Aspirin and Heparin to Increase the Hemocompatibility of Artificial Vascular Grafts.

Hosseinzadeh S, Shams F, Fattahi R, Nuoroozi G, Rostami E, Shahghasempour L Adv Pharm Bull. 2023; 13(1):123-133.

PMID: 36721809 PMC: 9871267. DOI: 10.34172/apb.2023.013.