Abstract

Background: Fitting four-parameter sigmoidal models is one of the methods established in the analysis of quantitative real-time PCR (qPCR) data. We had observed that these models are not optimal in the fitting outcome due to the inherent constraint of symmetry around the point of inflection. Thus, we found it necessary to employ a mathematical algorithm that circumvents this problem and which utilizes an additional parameter for accommodating asymmetrical structures in sigmoidal qPCR data.

Results: The four-parameter models were compared to their five-parameter counterparts by means of nested F-tests based on the residual variance, thus acquiring a statistical measure for higher performance. For nearly all qPCR data we examined, five-parameter models resulted in a significantly better fit. Furthermore, accuracy and precision for the estimation of efficiencies and calculation of quantitative ratios were assessed with four independent dilution datasets and compared to the most commonly used quantification methods. It could be shown that the five-parameter model exhibits an accuracy and precision more similar to the non-sigmoidal quantification methods.

Conclusion: The five-parameter sigmoidal models outperform the established four-parameter model with high statistical significance. The estimation of essential PCR parameters such as PCR efficiency, threshold cycles and initial template fluorescence is more robust and has smaller variance. The model is implemented in the qpcR package for the freely available statistical R environment. The package can be downloaded from the author's homepage.

Citing Articles

High-Yield α-Synuclein Purification and Ionic Strength Modification Pivotal to Seed Amplification Assay Performance and Reproducibility.

Janarthanam C, Clabaugh G, Wang Z, Melvin B, Scheibe I, Jin H Int J Mol Sci. 2024; 25(11).

PMID: 38892177 PMC: 11172462. DOI: 10.3390/ijms25115988.


A cobalt concentration sensitive Btu-like system facilitates cobalamin uptake in sp. PCC 7120.

Graf J, Fresenborg L, Seitz H, Pernil R, Schleiff E Microb Cell. 2024; 11:41-56.

PMID: 38379927 PMC: 10878165. DOI: 10.15698/mic2024.02.814.


Introducing the f% method: a reliable and accurate approach for qPCR analysis.

Gamal M, Ibrahim M BMC Bioinformatics. 2024; 25(1):17.

PMID: 38212692 PMC: 10782791. DOI: 10.1186/s12859-024-05630-y.


Quantitative mRNA expression measurement at home.

Pandey S, McCoy S, Stobdan T, Sahoo D Sci Rep. 2024; 14(1):1013.

PMID: 38200031 PMC: 10781964. DOI: 10.1038/s41598-023-49651-8.


Were public interventions relevant for containing the covid-19 pandemic in Brazil in 2020?.

Cattani V, Santos T, Ribeiro-Alves M, Castro-Alves J Rev Saude Publica. 2023; 57:77.

PMID: 37937651 PMC: 10609658. DOI: 10.11606/s1518-8787.2023057005030.


References
1.
Skern R, Frost P, Nilsen F . Relative transcript quantification by quantitative PCR: roughly right or precisely wrong?. BMC Mol Biol. 2005; 6:10. PMC: 1090581. DOI: 10.1186/1471-2199-6-10. View

2.
Klein D . Quantification using real-time PCR technology: applications and limitations. Trends Mol Med. 2002; 8(6):257-60. DOI: 10.1016/s1471-4914(02)02355-9. View

3.
van der Graaf P, Schoemaker R . Analysis of asymmetry of agonist concentration-effect curves. J Pharmacol Toxicol Methods. 1999; 41(2-3):107-15. DOI: 10.1016/s1056-8719(99)00026-x. View

4.
Rutledge R . Sigmoidal curve-fitting redefines quantitative real-time PCR with the prospective of developing automated high-throughput applications. Nucleic Acids Res. 2004; 32(22):e178. PMC: 545475. DOI: 10.1093/nar/gnh177. View

5.
Liu W, Saint D . Validation of a quantitative method for real time PCR kinetics. Biochem Biophys Res Commun. 2002; 294(2):347-53. DOI: 10.1016/S0006-291X(02)00478-3. View