Voiding Pattern Analysis As a Surrogate for Cystometric Evaluation in Uroplakin II Knockout Mice
Overview
Authors
Affiliations
Purpose: Previous study has shown that the absence of uroplakin II can cause urinary tract dysfunction, including vesicoureteral reflux and renal abnormalities, as well as micturition pattern changes. We developed a simple surrogate measure of bladder function using ultraviolet visualization of urinary voiding patterns in a uroplakin II knockout mouse animal model.
Materials And Methods: Three male and 3 female WT mice, and 3 male and 3 female uroplakin II knockout mice were evaluated by cystometric analysis and voiding pattern markings. Voiding pattern markings were graded by independent observers on a scale of 1 to 5 according to the degree of dispersion of voided urine. Statistical analysis was then used to correlate voiding dispersion grades with cystometric parameters in the same mice.
Results: The degree of dispersion of voiding pattern markings correlated with several measures of bladder function. Specifically the Pearson correlation coefficients for the observed voiding patterns highly correlated with baseline pressure, threshold pressure and intermicturition pressure measurements made during conscious cystometry in these mice (p <0.05).
Conclusions: Ultraviolet visualization of urinary voiding patterns of mice correlated well with certain measures of standard cystometric evaluations. As such, this method provides a simple, noninvasive method of evaluating mouse bladder function. Implementation of this methodology, which can potentially be automated for high throughput analysis, can accelerate the development of novel therapy for certain important aspects of bladder disease/dysfunction.
Automated identification and segmentation of urine spots based on deep-learning.
Fan X, Li J, Yan J PeerJ. 2024; 12:e17398.
PMID: 39035153 PMC: 11260409. DOI: 10.7717/peerj.17398.
Vidal-Martinez G, Najera K, Miranda J, Gil-Tommee C, Yang B, Vargas-Medrano J Neuroscience. 2019; 411:1-10.
PMID: 31129200 PMC: 6612448. DOI: 10.1016/j.neuroscience.2019.05.029.
Gil-Tommee C, Vidal-Martinez G, Annette Reyes C, Vargas-Medrano J, Herrera G, Martin S Exp Neurol. 2018; 311:265-273.
PMID: 30393144 PMC: 6319267. DOI: 10.1016/j.expneurol.2018.10.014.
Void spot assay: recommendations on the use of a simple micturition assay for mice.
Hill W, Zeidel M, Bjorling D, Vezina C Am J Physiol Renal Physiol. 2018; 315(5):F1422-F1429.
PMID: 30156116 PMC: 6293303. DOI: 10.1152/ajprenal.00350.2018.
Evaluating the voiding spot assay in mice: a simple method with complex environmental interactions.
Chen H, Zhang L, Hill W, Yu W Am J Physiol Renal Physiol. 2017; 313(6):F1274-F1280.
PMID: 28835420 PMC: 5814640. DOI: 10.1152/ajprenal.00318.2017.