» Articles » PMID: 18289938

Validity of the Use of a Fixed Point for Intracycle Velocity Calculations in Swimming

Overview
Journal J Sci Med Sport
Specialty Orthopedics
Date 2008 Feb 22
PMID 18289938
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

The intracycle velocity (V) of a fixed point on a swimmer's body, usually the hip, is frequently calculated as a direct indication of the intracycle V of the centre of mass (CM). The purpose of this study was to examine whether the intracycle V of the hip reflects accurately the intracycle V of the CM in freestyle swimming. One stroke cycle was analysed for ten swimmers performing a maximum freestyle swim. The magnitude of differences between CM and hip values was calculated for the instantaneous V values, the intracycle V fluctuation (V(fluc)) and the magnitude and timing of appearance of maximum (V(max)) and minimum intracycle V (V(min)). Large differences were found in all variables, with the use of the hip for V calculations overestimating significantly V(max) and underestimating significantly V(min) and V(fluc) of the CM (p< or =0.001). The results of this study showed that the hip motion should not be used as an indication of the intracycle CM motion in freestyle swimming.

Citing Articles

Intracycle Velocity Variation in Swimming: A Systematic Scoping Review.

Fernandes A, Afonso J, Noronha F, Mezencio B, Vilas-Boas J, Fernandes R Bioengineering (Basel). 2023; 10(3).

PMID: 36978699 PMC: 10044880. DOI: 10.3390/bioengineering10030308.


Impact of COVID-19 on Swimming Training: Practical Recommendations during Home Confinement/Isolation.

Haddad M, Abbes Z, Mujika I, Chamari K Int J Environ Res Public Health. 2021; 18(9).

PMID: 33947100 PMC: 8124287. DOI: 10.3390/ijerph18094767.


Comparison of Classical Kinematics, Entropy, and Fractal Properties As Measures of Complexity of the Motor System in Swimming.

Barbosa T, Goh W, Morais J, Costa M, Pendergast D Front Psychol. 2016; 7:1566.

PMID: 27774083 PMC: 5053984. DOI: 10.3389/fpsyg.2016.01566.


Reliability of Three-Dimensional Linear Kinematics and Kinetics of Swimming Derived from Digitized Video at 25 and 50 Hz with 10 and 5 Frame Extensions to the 4(th) Order Butterworth Smoothing Window.

Sanders R, Gonjo T, McCabe C J Sports Sci Med. 2015; 14(2):441-51.

PMID: 25983595 PMC: 4424475.


Reliability of the elliptical zone method of estimating body segment parameters of swimmers.

Sanders R, Chiu C, Gonjo T, Thow J, Oliveira N, Psycharakis S J Sports Sci Med. 2015; 14(1):215-24.

PMID: 25729310 PMC: 4306775.