» Articles » PMID: 18257918

Comparison of Normalisation Methods for Surface-enhanced Laser Desorption and Ionisation (SELDI) Time-of-flight (TOF) Mass Spectrometry Data

Overview
Publisher Biomed Central
Specialty Biology
Date 2008 Feb 9
PMID 18257918
Citations 21
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Mass spectrometry for biological data analysis is an active field of research, providing an efficient way of high-throughput proteome screening. A popular variant of mass spectrometry is SELDI, which is often used to measure sample populations with the goal of developing (clinical) classifiers. Unfortunately, not only is the data resulting from such measurements quite noisy, variance between replicate measurements of the same sample can be high as well. Normalisation of spectra can greatly reduce the effect of this technical variance and further improve the quality and interpretability of the data. However, it is unclear which normalisation method yields the most informative result.

Results: In this paper, we describe the first systematic comparison of a wide range of normalisation methods, using two objectives that should be met by a good method. These objectives are minimisation of inter-spectra variance and maximisation of signal with respect to class separation. The former is assessed using an estimation of the coefficient of variation, the latter using the classification performance of three types of classifiers on real-world datasets representing two-class diagnostic problems. To obtain a maximally robust evaluation of a normalisation method, both objectives are evaluated over multiple datasets and multiple configurations of baseline correction and peak detection methods. Results are assessed for statistical significance and visualised to reveal the performance of each normalisation method, in particular with respect to using no normalisation. The normalisation methods described have been implemented in the freely available MASDA R-package.

Conclusion: In the general case, normalisation of mass spectra is beneficial to the quality of data. The majority of methods we compared performed significantly better than the case in which no normalisation was used. We have shown that normalisation methods that scale spectra by a factor based on the dispersion (e.g., standard deviation) of the data clearly outperform those where a factor based on the central location (e.g., mean) is used. Additional improvements in performance are obtained when these factors are estimated locally, using a sliding window within spectra, instead of globally, over full spectra. The underperforming category of methods using a globally estimated factor based on the central location of the data includes the method used by the majority of SELDI users.

Citing Articles

Predicting Preterm Birth Using Proteomics.

Maric I, Stevenson D, Aghaeepour N, Gaudilliere B, Wong R, Angst M Clin Perinatol. 2024; 51(2):391-409.

PMID: 38705648 PMC: 11186213. DOI: 10.1016/j.clp.2024.02.011.


Organ-specific extracellular matrix directs trans-differentiation of mesenchymal stem cells and formation of salivary gland-like organoids in vivo.

Tran O, Wang H, Li S, Malakhov A, Sun Y, Abdul Azees P Stem Cell Res Ther. 2022; 13(1):306.

PMID: 35841112 PMC: 9284714. DOI: 10.1186/s13287-022-02993-y.


Matrix-bound Cyr61/CCN1 is required to retain the properties of the bone marrow mesenchymal stem cell niche but is depleted with aging.

Marinkovic M, Dai Q, Gonzalez A, Tran O, Block T, Harris S Matrix Biol. 2022; 111:108-132.

PMID: 35752272 PMC: 10069241. DOI: 10.1016/j.matbio.2022.06.004.


Rapid diagnosis of periodontitis, a feasibility study using MALDI-TOF mass spectrometry.

Antezack A, Chaudet H, Tissot-Dupont H, Brouqui P, Monnet-Corti V PLoS One. 2020; 15(3):e0230334.

PMID: 32168352 PMC: 7069628. DOI: 10.1371/journal.pone.0230334.


Identification of diagnostic metabolic signatures in clear cell renal cell carcinoma using mass spectrometry imaging.

Vijayalakshmi K, Shankar V, Bain R, Nolley R, Sonn G, Kao C Int J Cancer. 2019; 147(1):256-265.

PMID: 31863456 PMC: 8571954. DOI: 10.1002/ijc.32843.


References
1.
Malyarenko D, Cooke W, Adam B, Malik G, Chen H, Tracy E . Enhancement of sensitivity and resolution of surface-enhanced laser desorption/ionization time-of-flight mass spectrometric records for serum peptides using time-series analysis techniques. Clin Chem. 2004; 51(1):65-74. PMC: 4507422. DOI: 10.1373/clinchem.2004.037283. View

2.
Dijkstra M, Vonk R, Jansen R . SELDI-TOF mass spectra: a view on sources of variation. J Chromatogr B Analyt Technol Biomed Life Sci. 2006; 847(1):12-23. DOI: 10.1016/j.jchromb.2006.11.004. View

3.
Hong H, Dragan Y, Epstein J, Teitel C, Chen B, Xie Q . Quality control and quality assessment of data from surface-enhanced laser desorption/ionization (SELDI) time-of flight (TOF) mass spectrometry (MS). BMC Bioinformatics. 2005; 6 Suppl 2:S5. PMC: 1637033. DOI: 10.1186/1471-2105-6-S2-S5. View

4.
John Semmes O, Feng Z, Adam B, Banez L, Bigbee W, Campos D . Evaluation of serum protein profiling by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry for the detection of prostate cancer: I. Assessment of platform reproducibility. Clin Chem. 2004; 51(1):102-12. DOI: 10.1373/clinchem.2004.038950. View

5.
Engwegen J, Helgason H, Cats A, Harris N, Bonfrer J, Schellens J . Identification of serum proteins discriminating colorectal cancer patients and healthy controls using surface-enhanced laser desorption ionisation-time of flight mass spectrometry. World J Gastroenterol. 2006; 12(10):1536-44. PMC: 4124285. DOI: 10.3748/wjg.v12.i10.1536. View