Comparison of Spectral and Entropic Measures for Surface Electromyography Time Series: a Pilot Study

Overview
Date 2008 Feb 6
PMID 18247257
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

In a previous study, we reported that the mean square displacement calculated from the surface electromyography (sEMG) signal of low back muscles exhibits a plateaulike behavior for intermediate times 20 ms < t < 400 ms. This property indicates the existence of correlations in the signal for times much longer than the inverse of the median frequency (MF), which is calculated from the power spectrum 1/<f> = 1/(100 Hz) = 10 ms, where <f> is the MF. This result suggests the use of methods from nonlinear analysis to characterize sEMG time series. In this study, we applied these techniques to sEMG signals and calculated the time-dependent entropy. The results showed that the entropy of physiological time series from nondisabled control subjects is higher than the entropy from subjects with low back pain (LBP). The entropy reveals properties of the sEMG signal that are not captured by the power spectrum. In turn, this suggests a possible benefit of entropy as a tool for the clinical assessment of LBP. Because the two groups of subjects were not matched by age, the physiological origin of the observed differences between groups could be attributed to either LBP, age, or both. Additional studies with larger sample sizes and age-matched subjects are needed to investigate the relationship between LBP and entropy.

Citing Articles

A Statistical Method for Exploratory Data Analysis Based on 2D and 3D Area under Curve Diagrams: Parkinson's Disease Investigation.

Sushkova O, Morozov A, Gabova A, Karabanov A, Illarioshkin S Sensors (Basel). 2021; 21(14).

PMID: 34300440 PMC: 8309570. DOI: 10.3390/s21144700.


Characterization of Pelvic Floor Activity in Healthy Subjects and with Chronic Pelvic Pain: Diagnostic Potential of Surface Electromyography.

Albaladejo-Belmonte M, Tarazona-Motes M, Nohales-Alfonso F, De-Arriba M, Alberola-Rubio J, Garcia-Casado J Sensors (Basel). 2021; 21(6).

PMID: 33806717 PMC: 8004809. DOI: 10.3390/s21062225.


Differential Changes with Age in Multiscale Entropy of Electromyography Signals from Leg Muscles during Treadmill Walking.

Kang H, Dingwell J PLoS One. 2016; 11(8):e0162034.

PMID: 27570974 PMC: 5003391. DOI: 10.1371/journal.pone.0162034.


Nonlinear parameters of surface EMG in schizophrenia patients depend on kind of antipsychotic therapy.

Meigal A, Miroshnichenko G, Kuzmina A, Rissanen S, Georgiadis S, Karjalainen P Front Physiol. 2015; 6:197.

PMID: 26217236 PMC: 4498039. DOI: 10.3389/fphys.2015.00197.


Non-Linear EMG Parameters for Differential and Early Diagnostics of Parkinson's Disease.

Meigal A, Rissanen S, Tarvainen M, Airaksinen O, Kankaanpaa M, Karjalainen P Front Neurol. 2013; 4:135.

PMID: 24062722 PMC: 3775312. DOI: 10.3389/fneur.2013.00135.