Abstract

Background: The left-ventricular ejection fraction (EF) and end-systolic volume (ESV) are strong predictors of prognosis for cardiac death. Gated myocardial perfusion single-photon emission computed tomography (gSPECT) may be used to measure ESV and EF. However, systematic differences may exist between referred populations. Our aim was to derive male and female reference limits for left-ventricular functional parameters, and determine the effect of age, weight, and body surface area (BSA).

Methods And Results: The ejection fraction and ESV were derived using QGS software for 127 patients with normal gSPECT studies. The lower reference limits of EF were 46.2% and 55.6% for men and women, respectively. The upper reference limits of ESV were 30.4 mL and 21.4 mL, and 15.7 mL/m(2) and 11.1 mL/m(2), when indexed to BSA for men and women, respectively. There was no correlation between EF and age, weight, or BSA (P > .05). There was a small decrease in ESV with age, and an increase with weight and BSA (P < .05). The sex-specific differences remained after adjusting for confounding variables.

Conclusions: We demonstrated a significant sex difference for all functional parameters measured, and we established the influence of patient age and weight. Local reference limits for ESV and EF have been established, and the latter are transferable to other departments operating similar protocols.

Citing Articles

CMR validation of left ventricular volumes and ejection fraction measured by the IQ-SPECT system in patients with small heart size.

Wei H, Wu J, Han K, Hu G, Wang H, Guo X EJNMMI Res. 2023; 13(1):33.

PMID: 37093329 PMC: 10126186. DOI: 10.1186/s13550-023-00987-2.


Relationship between Semi-Quantitative Parameters of Thallium-201 Myocardial Perfusion Imaging and Coronary Artery Disease.

Chang C, Yang M, Liu C, Chu H, Lin C, Yen W Diagnostics (Basel). 2020; 10(10).

PMID: 33007898 PMC: 7600615. DOI: 10.3390/diagnostics10100772.


Insights from physiology applied to interpretation of supranormal ejection fraction in women.

Kerkhof P, Handly N Eur Heart J Cardiovasc Imaging. 2020; 21(4):375-377.

PMID: 32068778 PMC: 7082723. DOI: 10.1093/ehjci/jeaa018.


Distribution of cardiac output to the brain across the adult lifespan.

Xing C, Tarumi T, Liu J, Zhang Y, Turner M, Riley J J Cereb Blood Flow Metab. 2016; 37(8):2848-2856.

PMID: 27789785 PMC: 5536794. DOI: 10.1177/0271678X16676826.


In vivo validation of gated myocardial SPECT imaging for quantification of small hearts: comparison with cardiac MRI.

Kondo C, Watanabe E, Momose M, Fukushima K, Abe K, Hagiwara N EJNMMI Res. 2016; 6(1):9.

PMID: 26857778 PMC: 4746205. DOI: 10.1186/s13550-015-0156-5.


References
1.
Slotwiner D, Devereux R, Schwartz J, Pickering T, De Simone G, Ganau A . Relation of age to left ventricular function in clinically normal adults. Am J Cardiol. 1998; 82(5):621-6. DOI: 10.1016/s0002-9149(98)00390-7. View

2.
Sharir T, Kang X, Germano G, Bax J, Shaw L, Gransar H . Prognostic value of poststress left ventricular volume and ejection fraction by gated myocardial perfusion SPECT in women and men: gender-related differences in normal limits and outcomes. J Nucl Cardiol. 2006; 13(4):495-506. DOI: 10.1016/j.nuclcard.2006.03.019. View

3.
De Bondt P, Van de Wiele C, De Sutter J, De Winter F, De Backer G, Dierckx R . Age- and gender-specific differences in left ventricular cardiac function and volumes determined by gated SPET. Eur J Nucl Med. 2001; 28(5):620-4. DOI: 10.1007/s002590100498. View

4.
Nichols K, Tamis J, DePuey E, MIERES J, Malhotra S, Rozanski A . Relationship of gated SPECT ventricular function parameters to angiographic measurements. J Nucl Cardiol. 1998; 5(3):295-303. DOI: 10.1016/s1071-3581(98)90131-3. View

5.
Ford P, Chatziioannou S, Moore W, Dhekne R . Overestimation of the LVEF by quantitative gated SPECT in simulated left ventricles. J Nucl Med. 2001; 42(3):454-9. View