» Articles » PMID: 18203465

Marginal and Internal Adaptation of Zirconium Dioxide Ceramic Copings and Crowns with Different Finish Line Designs

Overview
Journal Dent Mater J
Specialty Dentistry
Date 2008 Jan 22
PMID 18203465
Citations 19
Authors
Affiliations
Soon will be listed here.
Abstract

The present study evaluated the marginal and internal adaptation of single-tooth zirconium dioxide (ZrO2) ceramic copings or crowns with three different finish line designs. Twenty-four steel dies were prepared for maxillary central incisor crowns with the following finish line designs: shoulder (S), rounded shoulder (RS), and chamfer (C) preparations. Twenty-four standardized ZrO2 ceramic copings were manufactured with a CAD/CAM system (Cercon Smart Ceramics), and the crowns were finalized by veneering with a feldspathic ceramic. Measurements for marginal and internal adaptation were performed at two stages: the copings and the completed crowns. No significant differences were observed between the three groups in terms of marginal discrepancy median value: S, 73/69; RS, 61/60; C, 64/55 (microm). However, significant differences in internal adaptation were widely found among all groups: S, 117/111; RS, 72/75; C, 56/57 (microm). As for intra-group comparisons of marginal and internal adaptation values for all groups, the differences were not significant. It was found that the finish line design seemingly wielded no influence on marginal adaptation of single-tooth ZrO2 ceramic copings and crowns. It was also observed that the marginal and internal adaptation values in the present study were all within the clinically acceptable range.

Citing Articles

Full-Mouth Rehabilitation of a Patient with Gummy Smile-Multidisciplinary Approach: Case Report.

Janosi K, Cerghizan D, Berneanu F, Kovacs A, Szasz A, Muresan I Medicina (Kaunas). 2023; 59(2).

PMID: 36837400 PMC: 9967420. DOI: 10.3390/medicina59020197.


evaluation of marginal and internal fit of 3-unit monolithic zirconia restorations fabricated using digital scanning technologies.

Ozal C, Ulusoy M J Adv Prosthodont. 2022; 13(6):373-384.

PMID: 35003553 PMC: 8712113. DOI: 10.4047/jap.2021.13.6.373.


Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems.

Kayikci O, Ates S Clin Oral Investig. 2021; 26(2):1283-1291.

PMID: 34331593 DOI: 10.1007/s00784-021-04102-4.


Marginal Fit of Full Contour Monolithic Zirconia in Different Thicknesses and Layered Zirconia Crowns.

Mohaghegh M, Firouzmandi M, Ansarifard E, Ramazani L J Int Soc Prev Community Dent. 2020; 10(5):652-658.

PMID: 33282776 PMC: 7685281. DOI: 10.4103/jispcd.JISPCD_25_20.


Fit of cobalt-chromium copings fabricated by the selective laser melting technology and casting method: A comparative evaluation using a profilometer.

Gholamrezaei K, Vafaee F, Afkari B, Firouz F, Seif M Dent Res J (Isfahan). 2020; 17(3):200-207.

PMID: 32774797 PMC: 7386369.