» Articles » PMID: 18193463

Use of Amplatzer Vascular Plug (AVP) in Emergency Embolisation: Preliminary Experience and Review of Literature

Overview
Journal Emerg Radiol
Date 2008 Jan 15
PMID 18193463
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Amplatzer Vascular Plug (AVP) is a device recently proposed for extra-cardiac procedures such as arterial and venous embolisation. In this paper, we assess the usefulness of AVP in emergency embolisation presenting our preliminary experience and reviewing the Literature. During the last year, we selected 31 patients for embolisation using AVP. The following nine procedures were performed in emergency (8 males, mean 72.4 years, range 57-85): four ruptured abdominal aortic aneurysm, one traumatic hepatic pseudoaneurysm with arterio-portal fistula, one carotid pseudoaneurysm due to neoplastic erosion, one renal tumor with active bleeding, one ruptured isolated iliac aneurysm and one ruptured hypogastric aneurysm. We used a total of 13 AVPs. The follow-up was carried out by computed tomography angiography (CTA) and/or contrast-enhanced ultrasound (CEUS), 3 months after the procedure and then every 3 months. We obtained immediate technical success in all nine cases. No rupture or dissection of the treated arteries occurred. We observed only an asymptomatic spasm. During a mean follow-up of 5.3 months (range 3-12 months), CTA and/or CEUS showed complete occlusion of the treated arteries. The AVP is useful in some emergency settings. In the authors' experience, the device allows precise, controlled release and can be deployed to the target more rapidly than other traditional methods. The device cannot be used in all patients due to limited ability to negotiate tortuous vessels and limited size availability. In our institution, the AVP is less expensive than alternatives. In our experience and as reported in the early literature, the device is easy to use, versatile, and achieved a high technical success rate. Further studies may confirm the effectiveness and demonstrate additional indications.

Citing Articles

Double-barrel plugging in a recurrent aorto-enteric fistula.

Ayyappan A, Valakkada J, Bursupalle M, Kannath S, Pitchai S Indian J Thorac Cardiovasc Surg. 2022; 38(4):422-425.

PMID: 35756567 PMC: 9218023. DOI: 10.1007/s12055-022-01342-1.


Efficacy, safety and usability of bronchial artery embolization using a new anti-reflux microcatheter in the management of haemoptysis.

Angileri S, Roda G, Arrichiello A, Signorelli G, Di Meglio L, Gurgitano M Acta Biomed. 2020; 91(10-S):e2020009.

PMID: 33245068 PMC: 8023073. DOI: 10.23750/abm.v91i10-S.10265.


Imaging guided percutaneous renal biopsy: do it or not?.

Pagnini F, Cervi E, Maestroni U, Agostini A, Borgheresi A, Piacentino F Acta Biomed. 2020; 91(8-S):81-88.

PMID: 32945282 PMC: 7944675. DOI: 10.23750/abm.v91i8-S.9990.


Basic embolization techniques: tips and tricks.

Ierardi A, Piacentino F, Pesapane F, Carnevale A, Curti M, Fontana F Acta Biomed. 2020; 91(8-S):71-80.

PMID: 32945281 PMC: 7944672. DOI: 10.23750/abm.v91i8-S.9974.


Radiation-induced brain cavernomas in elderly: review of the literature and a rare case report.

Mariniello G, De Liso M, Russo C, Del Vecchio W, de Divitiis O, Bruno F Acta Biomed. 2019; 90(5-S):77-83.

PMID: 31085976 PMC: 6625569. DOI: 10.23750/abm.v90i5-S.8328.


References
1.
Carrafiello G, Lagana D, Dizonno M, Mangini M, Fugazzola C . Endovascular ligature of splenic artery aneurysm with Amplatzer Vascular Plug: a case report. Cardiovasc Revasc Med. 2007; 8(3):203-6. DOI: 10.1016/j.carrev.2006.11.002. View

2.
Lagana D, Carrafiello G, Mangini M, Dionigi G, Caronno R, Castelli P . Multimodal approach to endovascular treatment of visceral artery aneurysms and pseudoaneurysms. Eur J Radiol. 2006; 59(1):104-11. DOI: 10.1016/j.ejrad.2006.02.004. View

3.
Beck A, Dagan T, Matitiau A, Bruckheimer E . Transcatheter closure of pulmonary arteriovenous malformations with amplatzer devices. Catheter Cardiovasc Interv. 2006; 67(6):932-7. DOI: 10.1002/ccd.20728. View

4.
Idowu O, Barodawala F, Nemeth A, Trerotola S . Dual use of an amplatzer device in the transcatheter embolization of a large high-flow renal arteriovenous fistula. J Vasc Interv Radiol. 2007; 18(5):671-6. DOI: 10.1016/j.jvir.2007.02.008. View

5.
Santoro G, Cappelli Bigazzi M, Palladino M, Russo M, Carrozza M, Calabro R . Comparison of percutaneous closure of large patent ductus arteriosus by multiple coils versus the Amplatzer duct occluder device. Am J Cardiol. 2004; 94(2):252-5. DOI: 10.1016/j.amjcard.2004.03.079. View