» Articles » PMID: 18184683

The Leicester Cough Monitor: Preliminary Validation of an Automated Cough Detection System in Chronic Cough

Overview
Journal Eur Respir J
Specialty Pulmonary Medicine
Date 2008 Jan 11
PMID 18184683
Citations 84
Authors
Affiliations
Soon will be listed here.
Abstract

Chronic cough is a common condition that presents to both primary and secondary care. Assessment and management are hampered by the absence of well-validated outcome measures. The present study comprises the validation of the Leicester Cough Monitor (LCM), an automated sound-based ambulatory cough monitor. Cough frequency was measured with the LCM and compared with coughs and other sounds counted manually over 2 h of a 6-h recording by two observers in nine patients with chronic cough in order to determine the sensitivity and specificity of the LCM. Automated cough frequency was also compared with manual counts from one observer in 15 patients with chronic cough and eight healthy subjects. All subjects underwent 6-h recordings. A subgroup consisting of six control and five patients with stable chronic cough underwent repeat automated measurements > or = 3 months apart. A further 50 patients with chronic cough underwent 24-h automated cough monitoring. The LCM had a sensitivity and specificity of 91 and 99%, respectively, for detecting cough and a false-positive rate of 2.5 events x h(-1). Mean+/-SEM automated cough counts x patient x h(-1) was 48+/-9 in patients with chronic cough and 2+/-1 in the control group (mean difference 46 counts x patient x h(-1); 95% confidence interval (CI) 20-71). The automated cough counts were repeatable (intra-subject SD 11.4 coughs x patient x h(-1); intra-class correlation coefficient 0.9). The cough frequency in patients undergoing 24-h automated monitoring was 19 coughs x patient x h(-1); daytime (08:00-22:00 h) cough frequency was significantly greater than overnight cough frequency (25 versus 10 coughs x patient x h(-1); mean difference 15 coughs x patient x h(-1), 95% CI 8-22). The Leicester Cough Monitor is a valid and reliable tool that can be used to assess 24-h cough frequency in patients with cough. It should be a useful tool to assess patients with cough in clinical trials and longitudinal studies.

Citing Articles

Cough monitoring systems in adults with chronic respiratory diseases: a systematic review.

Witjaksono L, Schulte M, Holland A, Wijsenbeek M, Khor Y Eur Respir Rev. 2025; 34(175).

PMID: 40044185 PMC: 11880901. DOI: 10.1183/16000617.0212-2023.


Performance evaluation of the smartphone-based AI cough monitoring app - Hyfe Cough Tracker against solicited respiratory sounds.

Galvosas M, Gabaldon-Figueira J, Keen E, Orrillo V, Blavia I, Chaccour J F1000Res. 2025; 11:730.

PMID: 39931660 PMC: 11809693. DOI: 10.12688/f1000research.122597.1.


Repeat expansions in gene in refractory chronic cough.

Hirons B, Cho P, Rhatigan K, Shaw J, Curro R, Rugginini B ERJ Open Res. 2025; 11(1.

PMID: 39811557 PMC: 11726589. DOI: 10.1183/23120541.00584-2024.


Decoding the impact of the placebo response in clinical trials for chronic cough.

Zhang M, Zhang B, Morice A ERJ Open Res. 2024; 10(5).

PMID: 39469270 PMC: 11514000. DOI: 10.1183/23120541.00335-2024.


An automatic cough counting method and system construction for portable devices.

Wang Y, Yang K, Xu S, Rui S, Xie J, Wang J Front Bioeng Biotechnol. 2024; 12:1477694.