Influence of Heart Rate on the Diagnostic Accuracy of Dual-source Computed Tomography Coronary Angiography
Overview
Authors
Affiliations
Objectives: We evaluated the influence of heart rate on image quality and diagnostic accuracy of dual-source computed tomography (DSCT) coronary angiography.
Background: Multidetector computed tomography (MDCT) coronary angiography has demonstrated an inverse relationship between heart rate and image quality. Dual-source CT provides a higher temporal resolution.
Methods: One hundred patients were studied by DSCT (DEFINITION, Siemens Medical Solutions, Forchheim, Germany). A contrast-enhanced volume dataset was acquired (two tubes, 120 kV, 400 mAs/rot, collimation 64 x 0.6 mm). Datasets were evaluated concerning the presence of significant coronary stenoses and validated against invasive coronary angiography.
Results: In 44 patients with a heart rate > or =65 beats/min, 566 of 616 coronary segments were evaluable (92%), whereas in 56 patients with a heart rate <65 beats/min, 777 of 778 coronary segments were evaluable (100%, p < 0.001). On a per-patient basis, 93% of patients (> or =65 beats/min) and 100% of patients (<65 beats/min) were considered evaluable. By classifying unevaluable segments as positive for stenosis, per-patient sensitivity was 95% (19 of 20) for heart rates > or =65 beats/min and 100% (22 of 22) for heart rates <65 beats/min. Specificity was 87% (21 of 24) versus 76% (26 of 34), and overall diagnostic accuracy was 91% (40 of 44) versus 86% (48 of 56). None of these differences were statistically significant. Similarly, no difference in diagnostic accuracy was found in per-vessel and -segment analyses.
Conclusions: In 100 patients studied without beta-blocker pre-medication, DSCT demonstrated slightly lower per-segment evaluability for high heart rates but no decrease in diagnostic accuracy for the detection of coronary artery stenoses.
Liu L, Shapira N, Sahbaee P, Litt H, Chen M, Noel P Proc SPIE Int Soc Opt Eng. 2023; 12304.
PMID: 37038393 PMC: 10082999. DOI: 10.1117/12.2646718.
Richards C, Obaid D Curr Cardiol Rev. 2019; 15(4):304-315.
PMID: 30806322 PMC: 8142354. DOI: 10.2174/1573403X15666190222163737.
Coronary CTA for Surveillance of Cardiac Allograft Vasculopathy.
Shah N, Blankstein R, Villines T, Imran H, Morrison A, Cheezum M Curr Cardiovasc Imaging Rep. 2018; 11(11):26.
PMID: 30464783 PMC: 6223999. DOI: 10.1007/s12410-018-9467-z.
Song I, Kang J, Kim M, Hwang H, Kim H, Ko S Korean J Radiol. 2018; 19(5):905-915.
PMID: 30174480 PMC: 6082753. DOI: 10.3348/kjr.2018.19.5.905.
Muster V, Wallner M, Schmidt A, Kapl M, von Lewinski F, Rainer P J Int Med Res. 2018; 46(6):2249-2257.
PMID: 29614895 PMC: 6023055. DOI: 10.1177/0300060518761302.