» Articles » PMID: 17952361

The Effects of Geometric and Threshold Definitions on Cortical Bone Metrics Assessed by in Vivo High-resolution Peripheral Quantitative Computed Tomography

Overview
Specialty Pathology
Date 2007 Oct 24
PMID 17952361
Citations 29
Authors
Affiliations
Soon will be listed here.
Abstract

This study evaluates in vivo methods for calculating cortical thickness (Ct.Th) with respect to sensitivity to tissue-level changes in mineralization and the ability to predict whole-bone mechanical properties. Distal radial and tibial images obtained from normal volunteers using high-resolution peripheral quantitative computed tomography (HR-pQCT) were segmented using three thresholds including the manufacturer default and +/-5% in terms of equivalent mineral density. Ct.Th was determined in two ways: using a direct three-dimensional (3D) method and using an annular method, where cortical bone volume is divided by periosteal surface area. D(comp) (mg HA/cm(3)) was calculated based on the mean density-calibrated linear attenuation values of the cortical compartment. Finite element analysis was performed to evaluate the predictive ability of the annular and direct Ct.Th methods. Using the direct 3D method, a +/-5% change in threshold resulted in a 2% mean difference in Ct.Th for both the radius and tibia. An average difference of 5% was found using the annular method. The change in threshold produced changes in D(comp) ranging 0.50-1.56% for both the tibia and radius. Annular Ct.Th correlated more strongly with whole-bone apparent modulus (R(2)=0.64 vs. R(2)=0.41). Both thickness calculation methods and threshold selection have a direct impact on cortical parameters derived from HR-pQCT images. Indirectly, these results suggest that moderate changes in tissue-level mineralization can affect cortical measures. Furthermore, while the direct 3D Ct.Th method is less sensitive to threshold effects, both methods are moderate predictors of mechanical strength, with the annular method being the stronger correlate.

Citing Articles

Integrating deep learning and machine learning for improved CKD-related cortical bone assessment in HRpQCT images: A pilot study.

Lee Y, Bandara W, Park S, Lee M, Seo C, Yang S Bone Rep. 2025; 24:101821.

PMID: 39866530 PMC: 11763521. DOI: 10.1016/j.bonr.2024.101821.


Protective effect of bisphosphonate on the cortical bone at key locations of the femur in aromatase inhibitor-associated bone loss: A three-dimensional cortical bone mapping study.

Hong N, Burm S, Treece G, Kim J, Kim M, Lee S J Bone Oncol. 2022; 32:100409.

PMID: 35024328 PMC: 8728402. DOI: 10.1016/j.jbo.2021.100409.


3D computational anatomy of the scaphoid and its waist for use in fracture treatment.

Ahrend M, Teunis T, Noser H, Schmidutz F, Richards G, Gueorguiev B J Orthop Surg Res. 2021; 16(1):216.

PMID: 33761965 PMC: 7988956. DOI: 10.1186/s13018-021-02330-8.


Guidelines for the assessment of bone density and microarchitecture in vivo using high-resolution peripheral quantitative computed tomography.

Whittier D, Boyd S, Burghardt A, Paccou J, Ghasem-Zadeh A, Chapurlat R Osteoporos Int. 2020; 31(9):1607-1627.

PMID: 32458029 PMC: 7429313. DOI: 10.1007/s00198-020-05438-5.


Computerized anatomy of the distal radius and its relevance to volar plating, research, and teaching.

Gehweiler D, Teunis T, Varjas V, Kerstan D, Gueorguiev B, Kamer L Clin Anat. 2018; 32(3):361-368.

PMID: 30521090 PMC: 7379250. DOI: 10.1002/ca.23320.