Initial Clinical Experience with the HeartMate II Axial-flow Left Ventricular Assist Device

Overview
Date 2007 Oct 20
PMID 17948075
Citations 15
Authors
Affiliations
Soon will be listed here.
Abstract

The redesigned HeartMate II, an axial-flow left ventricular assist device, is simpler, smaller, and easier to operate than are pulsatile pumps. These design characteristics should make the HeartMate II more reliable and durable and broaden the eligible population base. We implanted the HeartMate II in 43 patients (average age, 42 yr). The indication for use was bridge-to-heart transplantation in 26 patients and destination therapy in 17. The average duration of device support was 258 days (range, 1-761 days), and cumulative duration, more than 31 patient-years. Hemodynamic function improved in all patients during support. By 48 hours after implantation, the mean cardiac index had increased from 1.9+/-0.27 L/(min.m(2)) (baseline) to 3.5+/-0.8 L/(min.m(2)), and the pulmonary capillary wedge pressure had decreased from 24.8+/-11 mmHg to 18.5+/-5.3 mmHg. Of the 43 patients, 35 were discharged from the hospital. Support is ongoing in 27 patients (longest duration, >700 days). Nine patients died during support. Four patients had sufficient heart recovery to undergo pump explantation. Three patients underwent transplantation. One patient underwent device replacement after the pump driveline was fractured in a skateboarding accident; the device was removed in another patient because of a pump-pocket infection after 749 days of support. Of the 10 patients in whom the HeartMate II replaced a failed HeartMate I, 8 were discharged from the hospital. We have seen excellent results with use of the HeartMate II. Functional status and quality of life have greatly improved in patients who survived the perioperative period.

Citing Articles

Ventricular Assist Devices: an Evolving Field.

Kubrusly L Braz J Cardiovasc Surg. 2019; 34(1):III-V.

PMID: 30810690 PMC: 6385822. DOI: 10.21470/1678-9741-2019-0043.


Current perspectives on mechanical circulatory support.

Schramm R, Morshuis M, Schoenbrodt M, Boergermann J, Hakim-Meibodi K, Hata M Eur J Cardiothorac Surg. 2019; 55(Suppl 1):i31-i37.

PMID: 30608535 PMC: 6526098. DOI: 10.1093/ejcts/ezy444.


Stroke and Intracranial Hemorrhage in HeartMate II and HeartWare Left Ventricular Assist Devices: A Systematic Review.

Cho S, Moazami N, Frontera J Neurocrit Care. 2017; 27(1):17-25.

PMID: 28324260 DOI: 10.1007/s12028-017-0386-7.


Long-term continuous-flow left ventricular assist devices (LVAD) as bridge to heart transplantation.

Pozzi M, Giraud R, Tozzi P, Bendjelid K, Robin J, Meyer P J Thorac Dis. 2015; 7(3):532-42.

PMID: 25922736 PMC: 4387421. DOI: 10.3978/j.issn.2072-1439.2015.01.45.


Durability of continuous-flow left ventricular assist devices: a systematic review.

Xie A, Phan K, Yan T Ann Cardiothorac Surg. 2014; 3(6):547-56.

PMID: 25512893 PMC: 4250558. DOI: 10.3978/j.issn.2225-319X.2014.11.01.


References
1.
Rose E, Levin H, Oz M, Frazier O, Macmanus Q, Burton N . Artificial circulatory support with textured interior surfaces. A counterintuitive approach to minimizing thromboembolism. Circulation. 1994; 90(5 Pt 2):II87-91. View

2.
Connelly J, Abrams J, Klima T, Vaughn W, Frazier O . Acquired commissural fusion of aortic valves in patients with left ventricular assist devices. J Heart Lung Transplant. 2003; 22(12):1291-5. DOI: 10.1016/s1053-2498(03)00028-7. View

3.
La Francesca S, Smith R, Gregoric I, Kar B, Myers T, Price J . Replacement of a malfunctioning HeartMate II left ventricular assist device in a 14-year-old after a sudden fall. J Heart Lung Transplant. 2006; 25(7):862-4. DOI: 10.1016/j.healun.2006.03.012. View

4.
Salzberg S, Lachat M, Zund G, Oechslin E, Schmid E, Debakey M . Left ventricular assist device as bridge to heart transplantation--lessons learned with the MicroMed DeBakey axial blood flow pump. Eur J Cardiothorac Surg. 2003; 24(1):113-8. DOI: 10.1016/s1010-7940(03)00179-9. View

5.
Frazier O, Myers T, Gregoric I, Khan T, Delgado R, Croitoru M . Initial clinical experience with the Jarvik 2000 implantable axial-flow left ventricular assist system. Circulation. 2002; 105(24):2855-60. DOI: 10.1161/01.cir.0000018167.47314.af. View