» Articles » PMID: 17925360

Intravenous 3D Digital Subtraction Angiography in the Diagnosis of Unruptured Intracranial Aneurysms

Overview
Specialty Neurology
Date 2007 Oct 11
PMID 17925360
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Recent progress in digital subtraction angiography (DSA) devices makes it possible to perform rotational angiography with high resolution and high sensitivity. We tried intravenous (IV) 3D DSA in patients who had undergone MR angiography (MRA) suggestive of unruptured intracranial aneurysms. IV 3D DSA can be used as an alternative method for imaging unruptured intracranial aneurysms suggested on MRA.

Citing Articles

IV Flat Detector CT Angiography in Flat Detector CT Image-Guided Minimally Invasive Surgery for the Treatment of Intracerebral Hypertensive Hemorrhage.

Shu Z, Wang W, Qiu Y, Zhang L, Zheng Y, Wang J AJNR Am J Neuroradiol. 2024; 45(5):581-587.

PMID: 38548307 PMC: 11288543. DOI: 10.3174/ajnr.A8186.


Optimising image quality in intravenous cerebral cone beam computed tomography.

Broadley L, Erskine B, Marshall E, Ewert K, Picker B J Med Radiat Sci. 2023; 71(1):26-34.

PMID: 37847044 PMC: 10920929. DOI: 10.1002/jmrs.735.


Time-resolved C-arm cone beam CT angiography (TR-CBCTA) imaging from a single short-scan C-arm cone beam CT acquisition with intra-arterial contrast injection.

Li Y, Garrett J, Li K, Wu Y, Johnson K, Schafer S Phys Med Biol. 2018; 63(7):075001.

PMID: 29494345 PMC: 6758554. DOI: 10.1088/1361-6560/aab346.


Direct percutaneous carotid artery stenting for a patient with absence of the common carotid artery.

Toyota S, Wakayama A, Yoshimine T Interv Neuroradiol. 2012; 18(3):320-5.

PMID: 22958772 PMC: 3442307. DOI: 10.1177/159101991201800312.

References
1.
Modic M, Weinstein M, Pavlicek W, Gallagher J, Duchesneau P, Buonocore E . Intravenous digital subtraction angiography: peripheral versus central injection of contrast material. Radiology. 1983; 147(3):711-5. DOI: 10.1148/radiology.147.3.6342032. View

2.
Ball Jr J, Lukin R, Tomsick T, Chambers A . Complications of intravenous digital subtraction angiography. Arch Neurol. 1985; 42(10):969-72. DOI: 10.1001/archneur.1985.04060090051013. View

3.
Korogi Y, Takahashi M, Katada K, Ogura Y, Hasuo K, Ochi M . Intracranial aneurysms: detection with three-dimensional CT angiography with volume rendering--comparison with conventional angiographic and surgical findings. Radiology. 1999; 211(2):497-506. DOI: 10.1148/radiology.211.2.r99ma02497. View

4.
Pinto R, Manuell M, KRICHEFF I . Complications of digital intravenous angiography: experience in 2488 cervicocranial examinations. AJR Am J Roentgenol. 1984; 143(6):1295-9. DOI: 10.2214/ajr.143.6.1295. View

5.
Missler U, Hundt C, Wiesmann M, Mayer T, Bruckmann H . Three-dimensional reconstructed rotational digital subtraction angiography in planning treatment of intracranial aneurysms. Eur Radiol. 2000; 10(4):564-8. DOI: 10.1007/s003300050961. View