Characterization of Noise Sources for Two Generations of Computed Radiography Systems Using Powder and Crystalline Photostimulable Phosphors

Overview
Journal Med Phys
Specialty Biophysics
Date 2007 Sep 21
PMID 17879798
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

The performances of two generations of computed radiography (CR) were tested and compared in terms of resolution and noise characteristics. The main aim was to characterize and quantify the noise sources in the images. The systems tested were (1) Agfa CR 25.0, a flying spot reader with powder phosphor image plates (MD 40.0); and (2) the Agfa DX-S, a line-scanning CR reader with needle crystal phosphor image plates (HD 5.0). For both systems, the standard metrics of presampled modulation transfer function (MTF), normalized noise power spectra (NNPS) and detective quantum efficiency (DQE) were measured using standard radiation quality RQA5 as defined by the International Electrotechnical Commission. The various noise sources contributing to the NNPS were separated by using knowledge of their relationship with air kerma, MTF, absorption efficiency and antialiasing filters. The DX-S MTF was superior compared with the CR 25.0. The maximum difference in MTF between the DX-S scan and CR 25.0 subscan directions was 0.13 at 1.3 mm(-1). For a nominal detector air kerma of 4 microGy, the peak DQE of the DX-S was 43 (+/-3)%, which was over double that of the CR 25.0 of 18 (+/-2)%. The additive electronic noise was negligible on the CR 25.0 but calculated to be constant 3.4 x 10(-7) (+/-0.4 x 10(-7)) mm2 at 3.9 microGy on the DX-S. The DX-S has improved image quality compared with a traditional flying spot reader. The separation of the noise sources indicates that the improvements in DQE of the DX-S are due not only to the higher quantum, efficiency and MTF, but also the lower structure, secondary quantum, and excess noise.

Citing Articles

Comprehensive image quality comparison of conventional and new flat panel detectors under bedside chest radiography beam conditions.

Maruyama S, Saitou H Radiol Phys Technol. 2024; 18(1):94-103.

PMID: 39538057 DOI: 10.1007/s12194-024-00859-x.


Simulation Analysis on the Performance of a Circular-Edge Technique in Measurements of the Modulation Transfer Function.

Maruyama S J Med Phys. 2023; 48(1):90-97.

PMID: 37342601 PMC: 10277299. DOI: 10.4103/jmp.jmp_54_22.


Development of a storage phosphor imaging system for proton pencil beam spot profile determination.

Setianegara J, Mazur T, Hao Y, Yang D, Li H Med Phys. 2021; 48(9):5459-5471.

PMID: 34318488 PMC: 9278562. DOI: 10.1002/mp.15139.


Storage Phosphors for Medical Imaging.

Leblans P, Vandenbroucke D, Willems P Materials (Basel). 2017; 4(6):1034-1086.

PMID: 28879966 PMC: 5448636. DOI: 10.3390/ma4061034.


The role of activator concentration and precipitate formation on optical and dosimetric properties of KCl:Eu(2+) storage phosphor detectors.

Hansel R, Xiao Z, Hu Y, Green O, Yang D, Li H Med Phys. 2013; 40(9):092104.

PMID: 24007173 PMC: 3765241. DOI: 10.1118/1.4817522.