» Articles » PMID: 17869469

Reproducibility of CT-based Bone Texture Parameters of Cancellous Calf Bone Samples: Influence of Slice Thickness

Overview
Journal Eur J Radiol
Specialty Radiology
Date 2007 Sep 18
PMID 17869469
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Bone microarchitecture is an important determinant of the fracture risk, independently of bone mineral density. At present, bone biopsy is required for microarchitecture assessment, and accessible non-invasive techniques are needed. In this study, we tested the short-term reproducibility and parameter changes of a non-invasive method for microarchitecture assessment with a medical computed tomography. Texture parameters (run lengths and co-occurrence) were extracted from bone sample images. Reproducibility and the influence of slice thickness (1, 3, 5 and 8mm) were also studied. After five repositionings, short-term reproducibility was found to be good. All run length parameters but one fell significantly with increasing slice thickness. Co-occurrence parameters showed different patterns of change. Short-term coefficients of variation of texture parameters used to assess bone microarchitecture were similar to those obtained elsewhere with other techniques. The results were influenced by slice thicknesses, emphasizing the importance of the conditions of acquisition.

Citing Articles

Robustness of radiomic features of benign breast lesions and hormone receptor positive/HER2-negative cancers across DCE-MR magnet strengths.

Whitney H, Drukker K, Edwards A, Papaioannou J, Medved M, Karczmar G Magn Reson Imaging. 2021; 82:111-121.

PMID: 34174331 PMC: 8386988. DOI: 10.1016/j.mri.2021.06.021.


Influence of CT acquisition and reconstruction parameters on radiomic feature reproducibility.

Midya A, Chakraborty J, Gonen M, Do R, Simpson A J Med Imaging (Bellingham). 2018; 5(1):011020.

PMID: 29487877 PMC: 5812985. DOI: 10.1117/1.JMI.5.1.011020.


Responsible Radiomics Research for Faster Clinical Translation.

Vallieres M, Zwanenburg A, Badic B, Rest C, Visvikis D, Hatt M J Nucl Med. 2017; 59(2):189-193.

PMID: 29175982 PMC: 5807530. DOI: 10.2967/jnumed.117.200501.


Texture analysis of acute myocardial infarction with CT: First experience study.

Hinzpeter R, Wagner M, Wurnig M, Seifert B, Manka R, Alkadhi H PLoS One. 2017; 12(11):e0186876.

PMID: 29095833 PMC: 5667797. DOI: 10.1371/journal.pone.0186876.


Assessment of slice thickness effect on visibility of inferior alveolar canal in cone beam computed tomography images.

Goodarzi Pour D, Arzi B, Shamshiri A Dent Res J (Isfahan). 2017; 13(6):527-531.

PMID: 28182059 PMC: 5256017. DOI: 10.4103/1735-3327.197041.