» Articles » PMID: 17826273

Thirty-year Results of a Prospective Study of Charnley Total Hip Arthroplasty by the Posterior Approach

Overview
Journal J Arthroplasty
Specialty Orthopedics
Date 2007 Sep 11
PMID 17826273
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

We present the results of 228 consecutive Charnley low friction hip arthroplasties, performed in 193 patients, between July 1972 and December 1976. Unusually for this time, all hips were inserted by the posterior approach without a trochanteric osteotomy. All patients were enrolled into a prospective study; both preoperative and postoperative clinical and radiologic findings were recorded. This series was independently reviewed in 1985 (Atrah SGK. Long-term follow-up of Charnley total hip replacement through posterior approach. MSc thesis, University of London, 1987) and again in 2002. The preoperative and perioperative findings were similar to contemporary series. Implant positioning was also assessed. Because of our stable population, only 2 patients were lost to follow-up. Our survivorship results show a 10-year survival of 93% deteriorating to a 30-year survival of 73% (+/-6.1). The survivors were assessed radiologically and scored clinically using the Merle d'Aubigné-Postel score with a mean value of 12. The reason for revision was also recorded. These results are comparable to other studies and justify the use of the posterior approach.

Citing Articles

Weight-shifting-based robot control system improves the weight-bearing rate and balance ability of the static standing position in hip osteoarthritis patients: a randomized controlled trial focusing on outcomes after total hip arthroplasty.

Miyazaki S, Yamako G, Arakawa H, Sakamoto T, Kawaguchi T, Ito K PeerJ. 2023; 11:e15397.

PMID: 37214101 PMC: 10199675. DOI: 10.7717/peerj.15397.


60 years of Charnley-Muller Alivium hip prosthesis: the revision percentage and tribo-corrosion sequelae after a mean of 27 years.

Milosev I, Trebse R, Cor A, Levasic V Arch Orthop Trauma Surg. 2023; 143(10):6021-6031.

PMID: 36928503 PMC: 10491690. DOI: 10.1007/s00402-023-04824-y.


Similar Biomechanical Behavior in Gait Analysis between Ceramic-on-Ceramic and Ceramic-on-XLPE Total Hip Arthroplasties.

Triantafyllou A, Papagiannis G, Nikolaou V, Papagelopoulos P, Babis G Life (Basel). 2021; 11(12).

PMID: 34947897 PMC: 8704359. DOI: 10.3390/life11121366.


External iliac pseudoaneurysm secondary to medial wall penetration of an acetabular screw: a rare cause of total hip arthroplasty failure 15 years after implantation.

Wilson J, Escobar G, Badrinathan B, Reimer N Arthroplast Today. 2019; 5(3):264-268.

PMID: 31516962 PMC: 6728537. DOI: 10.1016/j.artd.2019.06.006.


Low friction arthroplasty and dual mobility cup: a new gold standard.

Prudhon J, Verdier R, Caton J Int Orthop. 2016; 41(3):563-571.

PMID: 27999924 DOI: 10.1007/s00264-016-3375-0.