Mechanical Power and Efficiency of Level Walking with Different Stride Rates
Overview
Authors
Affiliations
Walking humans prefer to use the stride rate that results in the lowest rate of metabolic energy expenditure. Mechanical power requirements have been suggested to underlie the metabolic response, but mechanical power is consistently reported to be minimal at stride rates 20-30% lower than preferred. This may be due to limitations in how total mechanical power has been computed, as well as a failure to account for the efficiency with which muscular work is done. We investigated how mechanical power and efficiency depend on stride rate in walking, with both quantities computed from the work done by the hip, knee and ankle joint moments. Our hypotheses were that mechanical power and efficiency are both optimized at the preferred stride rate, which would explain why metabolic energy expenditure is minimized at this rate. Contrary to our hypotheses, mechanical power curves exhibited plateaus that spanned stride rates lower than preferred (predicted optima: 11-12% below preferred), while net mechanical efficiency exhibited a plateau that spanned stride rates higher than preferred (predicted optimum: 8% above preferred). As expected, preferred stride rate (54.3 strides min(-1)) was not different from the stride rate that minimized net metabolic energy expenditure (predicted optimum: 0.2% above preferred). Given that mechanical power and mechanical efficiency exhibited plateaus on opposite sides of the preferred stride rate, the preferred rate in walking likely represents a compromise between these two factors. This may also explain the relative flatness of the curve for metabolic rate in the vicinity of the preferred stride rate.
Analysis of kinematic and kinetic changes in scoliosis following spinal manipulation.
Gou Y, Meng L, Chen S, Jiang Z, Lei H Sci Rep. 2025; 15(1):3881.
PMID: 39890882 PMC: 11785762. DOI: 10.1038/s41598-025-87812-z.
Move less, spend more: the metabolic demands of short walking bouts.
Luciano F, Ruggiero L, Minetti A, Pavei G Proc Biol Sci. 2024; 291(2033):20241220.
PMID: 39410664 PMC: 11521144. DOI: 10.1098/rspb.2024.1220.
Luciano F, Ruggiero L, Minetti A, Pavei G Sci Rep. 2024; 14(1):8970.
PMID: 38637567 PMC: 11026468. DOI: 10.1038/s41598-024-59171-8.
Cherni Y, Blache Y, Begon M, Ballaz L, Dal Maso F Sensors (Basel). 2023; 23(21).
PMID: 37960500 PMC: 10650199. DOI: 10.3390/s23218800.
Metabolic cost and mechanical work of walking in a virtual reality emulator.
Luciano F, Minetti A, Pavei G Eur J Appl Physiol. 2023; 124(3):783-792.
PMID: 37776345 PMC: 10879236. DOI: 10.1007/s00421-023-05306-0.