Contact-free Measurement of Cardiac Pulse Based on the Analysis of Thermal Imagery

Overview
Date 2007 Aug 19
PMID 17694862
Citations 56
Authors
Affiliations
Soon will be listed here.
Abstract

We have developed a novel method to measure human cardiac pulse at a distance. It is based on the information contained in the thermal signal emitted from major superficial vessels. This signal is acquired through a highly sensitive thermal imaging system. Temperature on the vessel is modulated by pulsative blood flow. To compute the frequency of modulation (pulse), we extract a line-based region along the vessel. Then, we apply fast Fourier transform (FFT) to individual points along this line of interest to capitalize on the pulse's thermal propagation effect. Finally, we use an adaptive estimation function on the average FFT outcome to quantify the pulse. We have carried out experiments on a data set of 34 subjects and compared the pulse computed from our thermal signal analysis method to concomitant ground-truth measurements obtained through a standard contact sensor (piezo-electric transducer). The performance of the new method ranges from 88.52% to 90.33% depending on the clarity of the vessel's thermal imprint. To the best of our knowledge, it is the first time that cardiac pulse has been measured several feet away from a subject with passive means.

Citing Articles

Agreement between Vital Signs Measured Using Mat-Type Noncontact Sensors and Those from Conventional Clinical Assessment.

Shimotori D, Otaka E, Sato K, Takasugi M, Yamakawa N, Shimizu A Healthcare (Basel). 2024; 12(12).

PMID: 38921307 PMC: 11203301. DOI: 10.3390/healthcare12121193.


Noise-Robust Pulse Wave Estimation from Near-Infrared Face Video Images Using the Wiener Estimation Method.

Hino Y, Ashida K, Ogawa-Ochiai K, Tsumura N J Imaging. 2023; 9(10).

PMID: 37888309 PMC: 10607892. DOI: 10.3390/jimaging9100202.


Non-contact measurement of neck pulses achieved by imaging micro-motions in the neck skin.

He Q, Geng W, Li W, Wang R Biomed Opt Express. 2023; 14(9):4507-4519.

PMID: 37791270 PMC: 10545184. DOI: 10.1364/BOE.501749.


Eye Segmentation Method for Telehealth: Application to the Myasthenia Gravis Physical Examination.

Lesport Q, Joerger G, Kaminski H, Girma H, McNett S, Abu-Rub M Sensors (Basel). 2023; 23(18).

PMID: 37765800 PMC: 10536520. DOI: 10.3390/s23187744.


A Digital Telehealth System to Compute the Myasthenia Gravis Core Examination Metrics.

Garbey M, Joerger G, Lesport Q, Girma H, McNett S, Abu-Rub M JMIR Neurotechnol. 2023; 2.

PMID: 37435094 PMC: 10334459. DOI: 10.2196/43387.