» Articles » PMID: 17674121

In Vitro Fluorescence Measurements and Monte Carlo Simulation of Laser Irradiation Propagation in Porcine Skin Tissue

Overview
Journal Lasers Med Sci
Publisher Springer
Date 2007 Aug 4
PMID 17674121
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

In dermatology, the in vivo spectral fluorescence measurements of human skin can serve as a valuable supplement to standard non-invasive techniques for diagnosing various skin diseases. However, quantitative analysis of the fluorescence spectra is complicated by the fact that skin is a complex multi-layered and inhomogeneous organ, with varied optical properties and biophysical characteristics. In this work, we recorded, in vitro, the laser-induced fluorescence emission signals of healthy porcine skin, one of the animals, which is considered as one of the most common models for investigations related to medical diagnostics of human cutaneous tissues. Differences were observed in the form and intensity of the fluorescence signal of the porcine skin, which can be attributed to the different concentrations of the native fluorophores and the variable physical and biological conditions of the skin tissue. As the light transport in the tissue target is directly influencing the absorption and the fluorescence emission signals, we performed Monte Carlo simulation of the light distribution in a five-layer model of human skin tissue, with a pulsed ultraviolet laser beam.

Citing Articles

Autofluorescence spectroscopy for nerve-sparing laser surgery of the head and neck-the influence of laser-tissue interaction.

Stelzle F, Rohde M, Riemann M, Oetter N, Adler W, Tangermann-Gerk K Lasers Med Sci. 2017; 32(6):1289-1300.

PMID: 28551764 DOI: 10.1007/s10103-017-2240-8.


Application of immunohistochemical staining to detect antigen destruction as a measure of tissue damage.

Onul A, Colvard M, Paradise W, Elseth K, Vesper B, Gouvas E J Histochem Cytochem. 2012; 60(9):683-93.

PMID: 22723525 PMC: 3524554. DOI: 10.1369/0022155412452146.

References
1.
Panjehpour M, Julius C, Phan M, Vo-Dinh T, Overholt S . Laser-induced fluorescence spectroscopy for in vivo diagnosis of non-melanoma skin cancers. Lasers Surg Med. 2002; 31(5):367-73. DOI: 10.1002/lsm.10125. View

2.
Durkin A, Richards-Kortum R . Comparison of methods to determine chromophore concentrations from fluorescence spectra of turbid samples. Lasers Surg Med. 1996; 19(1):75-89. DOI: 10.1002/(SICI)1096-9101(1996)19:1<75::AID-LSM9>3.0.CO;2-N. View

3.
Kollias N, Gillies R, Moran M, Kochevar I, Anderson R . Endogenous skin fluorescence includes bands that may serve as quantitative markers of aging and photoaging. J Invest Dermatol. 1998; 111(5):776-80. DOI: 10.1046/j.1523-1747.1998.00377.x. View

4.
Arimoto H, Egawa M, Yamada Y . Depth profile of diffuse reflectance near-infrared spectroscopy for measurement of water content in skin. Skin Res Technol. 2005; 11(1):27-35. DOI: 10.1111/j.1600-0846.2005.00093.x. View

5.
Pfefer T, Paithankar D, Poneros J, Schomacker K, Nishioka N . Temporally and spectrally resolved fluorescence spectroscopy for the detection of high grade dysplasia in Barrett's esophagus. Lasers Surg Med. 2003; 32(1):10-6. DOI: 10.1002/lsm.10136. View