» Articles » PMID: 17669525

Using Ultrafiltration to Concentrate and Detect Bacillus Anthracis, Bacillus Atrophaeus Subspecies Globigii, and Cryptosporidium Parvum in 100-liter Water Samples

Overview
Specialty Microbiology
Date 2007 Aug 3
PMID 17669525
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

A strategy that uses ultrafiltration (UF) to concentrate microorganisms from water samples has been developed and tested. This strategy was tested using 100-liter water samples with volume reduction achieved through ultrafiltration and recycling the microorganisms of interest through a retentate vessel, rather than returning them to the sample container, where they might pose an incremental hazard to sample takers or the environment. Three protocols based on this strategy were tested. The first protocol entailed sample volume reduction and collection of the final reduced sample. The second and third protocols both incorporated pretreatment of the filter and fluid lines with a solution to prevent microorganisms from adhering. In the second protocol, the filter was back flushed with a surfactant solution to recover microorganisms. The third protocol used recirculation of a surfactant solution to recover microorganisms. Tests were undertaken using 100-liter water samples spiked with approximately 100 or 1000 microorganisms (1 or 10 per liter). Test microorganisms included Bacillus anthracis Sterne strain, Bacillus atrophaeus subsp. globigii, and Cryptosporidium parvum. The first protocol had significantly lower recovery than the other two. Back flushing resulted in higher recovery than forward flushing, but the difference was not statistically significant.

Citing Articles

Comparison of liquid and filter sampling techniques for recovery of Bacillus spores and Escherichia coli from environmental water.

Abdel-Hady A, Monge M, Aslett D, Mikelonis A, Touati A, Ratliff K J Environ Manage. 2024; 370:122711.

PMID: 39366227 PMC: 11836889. DOI: 10.1016/j.jenvman.2024.122711.


Impact of filter material and holding time on spore sampling efficiency in water.

Ratliff K, Abdel-Hady A, Monge M, Mikelonis A, Touati A Lett Appl Microbiol. 2023; 76(2).

PMID: 36705271 PMC: 10599418. DOI: 10.1093/lambio/ovad005.


Development of Moore Swab and Ultrafiltration Concentration and Detection Methods for Typhi and Paratyphi A in Wastewater and Application in Kolkata, India and Dhaka, Bangladesh.

Liu P, Ibaraki M, Kapoor R, Amin N, Das A, Miah R Front Microbiol. 2021; 12:684094.

PMID: 34335510 PMC: 8320291. DOI: 10.3389/fmicb.2021.684094.


Evaluation of a modified rapid viability-polymerase chain reaction method for Bacillus atrophaeus spores in water matrices.

Bushon R, Brady A, Kephart C, Gallardo V J Microbiol Methods. 2021; 188:106293.

PMID: 34324928 PMC: 8488907. DOI: 10.1016/j.mimet.2021.106293.


The use of hollow fiber dialysis filters operated in axial flow mode for recovery of microorganisms in large volume water samples with high loadings of particulate matter.

Gallardo V, Morris B, Rhodes E J Microbiol Methods. 2019; 160:143-153.

PMID: 30974128 PMC: 6528822. DOI: 10.1016/j.mimet.2019.04.005.