Application of the Noise Power Spectrum in Modern Diagnostic MDCT: Part I. Measurement of Noise Power Spectra and Noise Equivalent Quanta

Overview
Journal Phys Med Biol
Publisher IOP Publishing
Date 2007 Aug 1
PMID 17664593
Citations 63
Authors
Affiliations
Soon will be listed here.
Abstract

Dose reduction efforts in diagnostic CT have brought the tradeoff of dose versus image quality to the forefront. The need for meaningful characterization of image noise beyond that offered by pixel standard deviation is becoming increasingly important. This work aims to study the implementation of the noise power spectrum (NPS) and noise equivalent quanta (NEQ) on modern, multislice diagnostic CT scanners. The details of NPS and NEQ measurement are outlined and special attention is paid to issues unique to multislice CT. Aliasing, filter design and effects of acquisition geometry are investigated. While it was found that both metrics can be implemented in modern CT, it was discovered that NEQ cannot be aptly applied with certain non-traditional reconstruction filters or in helical mode. NPS and NEQ under a variety of conditions are examined. Extensions of NPS and NEQ to uses in protocol standardization are also discussed.

Citing Articles

Noise-related inaccuracies in the quantitative evaluation of CT artifacts.

Hoyoshi K, Sato K, Homma N, Mori I Radiol Phys Technol. 2025; 18(1):157-171.

PMID: 39776374 DOI: 10.1007/s12194-024-00869-9.


Performance improvements of virtual monoenergetic images in photon-counting detector CT compared with dual source dual-energy CT: Fourier-based assessment.

Kawashima H, Ichikawa K, Yoshida R, Katayama T, Arimoto M, Kataoka J Phys Eng Sci Med. 2024; .

PMID: 39658761 DOI: 10.1007/s13246-024-01499-6.


Evaluation of SR-DLR in low-dose abdominal CT: superior image quality and noise reduction.

Tamura A, Mukaida E, Ota Y, Abe S, Orii M, Ieko Y Abdom Radiol (NY). 2024; .

PMID: 39560744 DOI: 10.1007/s00261-024-04686-x.


Development, validation, and application of a generic image-based noise addition method for simulating reduced dose computed tomography images.

Alsaihati N, Solomon J, McCrum E, Samei E Med Phys. 2024; 52(1):171-187.

PMID: 39387993 PMC: 11700769. DOI: 10.1002/mp.17444.


Effect of frame rate on image quality in cardiology evaluated using an indirect conversion dynamic flat-panel detector.

Hasegawa A, Kondo Y Radiol Phys Technol. 2024; 17(4):947-954.

PMID: 39292344 DOI: 10.1007/s12194-024-00845-3.