Long-term Compliance and Side Effects of Oral Appliances Used for the Treatment of Snoring and Obstructive Sleep Apnea Syndrome
Overview
Psychiatry
Authors
Affiliations
Study Objective: This study, by means of a mail survey, quantified the compliance with and side effects of the use of an oral appliance for more than five years in patients with snoring or obstructive sleep apnea.
Methods: A questionnaire was mailed to 544 patients who used an oral appliance for the treatment of snoring or obstructive sleep apnea.
Results: Some 46.1% of the patients returned the questionnaire, 37.8% did not, 15% had an invalid address, and 0.9% were deceased. The mean time period between oral appliance insertion and the return date of these surveys was 5.7 +/- 3.5 years. Of the returned sample, 64.1% were wearing their oral appliance (users). There was no significant difference in the baseline and post-titration respiratory disturbance index between the returned and not-returned groups or between patients who had stopped wearing the oral appliance (nonusers) and users. Within the users group, 93.7% used the oral appliance more than 4 nights per week, 100% wore it more than half of each night, and 95% were satisfied with the treatment. The most frequent reasons why patients discontinued wear were uncomfortable (44.4%), had little or no effect (33.6%), or switched to nasal continuous positive airway pressure (23.3%). Snoring was satisfactorily controlled in 75.6% of users and in 43.2% of nonusers. Side effects, such as dry mouth and tooth and/or jaw discomfort, were more frequent and more severe in the nonusers (P < .05). With oral appliance usage, both users and nonusers reported an increase in temporomandibular joint symptoms, but there was no difference in the degree of change.
Conclusions: Subjects who were compliant with oral appliance therapy reported long periods of use and adequate control of snoring.
Gurgel M, Kurita L, Fonteles C, Ribeiro T, Costa F, Freitas B Sleep Sci. 2024; 16(4):e381-e388.
PMID: 38197027 PMC: 10773499. DOI: 10.1055/s-0043-1776870.
Sangalli L, Yanez-Regonesi F, Moreno-Hay I J Clin Sleep Med. 2023; 20(4):487-496.
PMID: 37909061 PMC: 10985294. DOI: 10.5664/jcsm.10900.
Buiret G, Molta C Sleep Breath. 2023; 28(1):555-560.
PMID: 37676348 DOI: 10.1007/s11325-023-02908-y.
Funahashi K, Hirose M, Kondo S, Sano Y, Fujita S, Iwata N Fujita Med J. 2023; 9(3):218-224.
PMID: 37554945 PMC: 10405904. DOI: 10.20407/fmj.2022-023.
Factors associated with treatment adherence to mandibular advancement devices: a scoping review.
van der Hoek L, Rosenmoller B, van de Rijt L, de Vries R, Aarab G, Lobbezoo F Sleep Breath. 2023; 27(6):2527-2544.
PMID: 37386300 PMC: 10656313. DOI: 10.1007/s11325-023-02862-9.