» Articles » PMID: 17526989

Accuracy of Nonstenotic Coronary Atherosclerosis Assessment by Multi-detector Computed Tomography

Abstract

Background: The ability to evaluate coronary stenosis using multi-detector computed tomography (MDCT) has been well discussed. In contrast, several studies demonstrated that the plaque burden measured by intravascular ultrasound (IVUS) has a relationship to the risk of cardiovascular events. the accuracy of MDCT was studied to determine plaque and vessel size compared with IVUS.

Methods And Results: Fifty-six proximal lesions (American College of Cardiology/American Heart Association classification: segment 1, 5, 6) from 33 patients were assessed using MDCT and IVUS. The plaque and vessel area were measured from the cross-sectional image using both MDCT and IVUS. Eight coronary artery lesions with motion artifacts and heavily calcified plaques were excluded from the analysis. The vessel and lumen size evaluated using MDCT were closely correlated with those evaluated by IVUS (R(2)=0.614, 0.750 respectively). Furthermore, there was a strong correlation between percentage plaque area assessed by MDCT and IVUS (R(2)=0.824).

Conclusion: MDCT can noninvasively quantify coronary atherosclerotic plaque with good correlation compared with IVUS in patients with atherosclerosis.

Citing Articles

Non-Calcified Coronary Artery Plaque on Coronary Computed Tomography Angiogram: Prevalence and Significance.

Alyami B, Santer M, Seetharam K, Velu D, Gadde E, Patel B Tomography. 2023; 9(5):1755-1771.

PMID: 37736993 PMC: 10514817. DOI: 10.3390/tomography9050140.


Recent perspective on coronary artery bifurcation interventions.

Dash D Heart Asia. 2016; 6(1):18-25.

PMID: 27326157 PMC: 4832703. DOI: 10.1136/heartasia-2013-010451.


Epicardial adipose tissue is associated with extensive coronary artery lesions in patients undergoing coronary artery bypass grafting: an observational study.

Kaya M, Yeniterzi M, Yazici P, Diker M, Celik O, Erturk M Maedica (Bucur). 2015; 9(2):135-43.

PMID: 25705268 PMC: 4296755.


Accuracy of dual-source CT in the characterisation of non-calcified plaque: use of a colour-coded analysis compared with virtual histology intravascular ultrasound.

Brodoefel H, Burgstahler C, Heuschmid M, Reimann A, Khosa F, Kopp A Br J Radiol. 2009; 82(982):805-12.

PMID: 19332517 PMC: 3292046. DOI: 10.1259/bjr/35768497.


Characterization of coronary atherosclerosis by dual-source computed tomography and HU-based color mapping: a pilot study.

Brodoefel H, Reimann A, Heuschmid M, Tsiflikas I, Kopp A, Schroeder S Eur Radiol. 2008; 18(11):2466-74.

PMID: 18491107 PMC: 3289943. DOI: 10.1007/s00330-008-1019-5.