» Articles » PMID: 1750527

Experimental Instrumentation and Left Ventricular Pressure-strain Relationship

Overview
Journal Am J Physiol
Specialty Physiology
Date 1991 Dec 1
PMID 1750527
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Pericardial pressure measurement with a balloon transducer requires opening and reapproximating the pericardium. If this instrumentation significantly compromises pericardial volume, the heart may be constrained, exaggerating the magnitude of pericardial pressure and thus altering the left ventricular end-diastolic pressure-volume relationship. In open-chest dogs, we studied the effects of opening the pericardium, inserting a pericardial balloon transducer and myocardial sonomicrometer crystals, and reapproximating the pericardium on the left ventricular end-diastolic pressure-strain relationship (LVEDPSR). After a thoracotomy, sonomicrometer crystals were inserted through small holes (less than 3 mm) in the pericardium to measure LV segment length. A micromanometer with a reference lumen was used to measure LV pressure. LVEDPSRs were recorded in the following situations: 1) before the pericardium was opened (but after the crystals were inserted); 2) after the pericardium was opened, the heart was instrumented (4 pairs of crystals and 1 balloon), and the pericardium was reapproximated with interrupted sutures; and 3) after the pericardium was removed. For each dog, a cubic regression equation was fitted to the data obtained before opening the pericardium, and the 95% confidence intervals for the individual data points were determined. In each case, the LVEDPSR obtained after instrumentation was similar to the LVEDPSR described before opening the pericardium. Furthermore, data obtained after instrumentation were uniformly located within the confidence intervals of the LVEDPSR obtained before opening the pericardium and instrumenting the heart.(ABSTRACT TRUNCATED AT 250 WORDS)

Citing Articles

A pharmacologic activator of endothelial KCa channels increases systemic conductance and reduces arterial pressure in an anesthetized pig model.

Mishra R, Mitchell J, Gibbons-Kroeker C, Wulff H, Belenkie I, Tyberg J Vascul Pharmacol. 2015; 79:24-31.

PMID: 26239885 PMC: 5710011. DOI: 10.1016/j.vph.2015.07.016.


Genesis of the characteristic pulmonary venous pressure waveform as described by the reservoir-wave model.

Bouwmeester J, Belenkie I, Shrive N, Tyberg J J Physiol. 2014; 592(17):3801-12.

PMID: 25015922 PMC: 4192704. DOI: 10.1113/jphysiol.2014.272963.


High-frequency oscillatory ventilation versus conventional ventilation: hemodynamic effects on lung and heart.

Smailys A, Mitchell J, Doig C, Tyberg J, Belenkie I Physiol Rep. 2014; 2(3):e00259.

PMID: 24760513 PMC: 4002239. DOI: 10.1002/phy2.259.


Wave reflections in the pulmonary arteries analysed with the reservoir-wave model.

Bouwmeester J, Belenkie I, Shrive N, Tyberg J J Physiol. 2014; 592(14):3053-62.

PMID: 24756638 PMC: 4214659. DOI: 10.1113/jphysiol.2014.273094.