» Articles » PMID: 17499871

Bladder Extension Variability During Pelvic External Beam Radiotherapy with a Full or Empty Bladder

Overview
Journal Radiother Oncol
Specialties Oncology
Radiology
Date 2007 May 15
PMID 17499871
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

Background And Purpose: Varying bladder fillings during radiotherapy lead to a changing dose-volume load to the bladder and adjacent structures. The aim of the study was to compare the extent of bladder wall movements during parallel series with full bladder (FB) and empty bladder (EB).

Materials And Methods: Three hundred and forty serial computed tomography (CT) scans were performed in 50 patients scheduled for primary and postoperative radiotherapy for prostate cancer. Each patient underwent two CT scans (with FB and EB) before and 2-3 times during radiotherapy. Displacements of the bladder wall were compared and correlated with changing bladder fillings.

Results: The variability of FB was larger compared to EB volume (standard deviation of 124 cc and 56 cc; p<0.01), but significant bladder wall displacement variabilities were only found at the anterior and superior borders. Within a bladder volume range between -100 and +200 ml relative to the FB planning scan, the mean bladder wall displacement remained < 5 mm at the inferior, lateral, and posterior borders - as opposed to 15 and 21 mm at the anterior and superior borders.

Conclusions: Treating the pelvis with EB compared to FB, bladder wall displacement can be only reduced at the superior and anterior borders. FB wall displacements are comparable with EB displacements at all other borders.

Citing Articles

Body Fluids Modulate Propagation of Tumor Treating Fields.

Wong E, Lok E Adv Radiat Oncol. 2024; 9(1):101316.

PMID: 38260214 PMC: 10801649. DOI: 10.1016/j.adro.2023.101316.


Bladder volume reproducibility after water consumption in patients with prostate cancer undergoing radiotherapy: A systematic review and meta-analysis.

Chen H, Lin P, Kuo L, Lin K, Fang C, Chi C Biomed J. 2022; 44(6 Suppl 2):S226-S234.

PMID: 35300945 PMC: 9068550. DOI: 10.1016/j.bj.2020.11.004.


Dynamic Changes in Bladder Morphology Over Time in Cervical Cancer Patients.

Jin F, Liu Q, Luo H, Zhu R, Mou Y, Wu Y Cancer Control. 2021; 28:10732748211021082.

PMID: 34060348 PMC: 8204530. DOI: 10.1177/10732748211021082.


Clinical implementation of magnetic resonance imaging guided adaptive radiotherapy for localized prostate cancer.

Tetar S, Bruynzeel A, Lagerwaard F, Slotman B, Bohoudi O, Palacios M Phys Imaging Radiat Oncol. 2021; 9:69-76.

PMID: 33458428 PMC: 7807673. DOI: 10.1016/j.phro.2019.02.002.


Magnetic resonance image-guided adaptive stereotactic body radiotherapy for prostate cancer: preliminary results of outcome and toxicity.

Ugurluer G, Atalar B, Mustafayev T, Gungor G, Aydin G, Sengoz M Br J Radiol. 2020; 94(1117):20200696.

PMID: 33095670 PMC: 7774684. DOI: 10.1259/bjr.20200696.