Comparison of a New Device for Blood Sampling in Cats with a Vacuum Tube Collection System - Plasma Biochemistry, Haematology and Practical Usage Assessment

Overview
Date 2007 May 15
PMID 17498993
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Using paediatric devices to collect venous blood from a cephalic vein in cats offers numerous practical advantages over traditional jugular venepuncture and vacuum closed systems: minimal restraint is required; there is minimal risk of serious injury to the cat; the discomfort associated with venepuncture is reduced by the use of small diameter (25 gauge) needles; very small volumes (200 microl) of blood are extracted; and the risk of vein collapse or haematoma is low. The aim of this study was to compare the haematological and plasma chemistry results obtained from six healthy cats using the two sampling techniques. Five plasma biochemical analytes were measured and a complete haematological examination was performed on each specimen. No clinically relevant difference between the two blood sampling techniques was observed for any variable, indicating that paediatric devices provide a useful alternative to vacuum tubes for venous blood collection in the cat.

Citing Articles

2022 ISFM/AAFP Cat Friendly Veterinary Environment Guidelines.

Taylor S, St Denis K, Collins S, Dowgray N, Ellis S, Heath S J Feline Med Surg. 2022; 24(11):1133-1163.

PMID: 36259498 PMC: 10845436. DOI: 10.1177/1098612X221128763.


Evaluation of eutectic lidocaine/prilocaine cream for jugular blood sampling in cats.

Crisi P, De Santis F, Giordano M, Cerasoli I, Colucci F, Di Tommaso M J Feline Med Surg. 2020; 23(2):185-189.

PMID: 32456515 PMC: 10741355. DOI: 10.1177/1098612X20917309.


Parameter Evaluation and Application Demonstration of a New Type of Blood Vacuum Tube Cap Opening and Closing Machine.

Pu R, Pu M, Xin Q, Chen F Iran J Public Health. 2019; 48(9):1600-1606.

PMID: 31700815 PMC: 6825677.


Repeated Blood Collection from Tail Vein of Non-Anesthetized Rats with a Vacuum Blood Collection System.

Zou W, Yang Y, Gu Y, Zhu P, Zhang M, Cheng Z J Vis Exp. 2017; (130).

PMID: 29286462 PMC: 5755556. DOI: 10.3791/55852.


Feline reference intervals for the Sysmex XT-2000iV and the ProCyte DX haematology analysers in EDTA and CTAD blood specimens.

Granat F, Geffre A, Bourges-Abella N, Mortier J, Theron M, Fauchon E J Feline Med Surg. 2013; 16(6):473-82.

PMID: 24226754 PMC: 11112188. DOI: 10.1177/1098612X13511811.

References
1.
Bland J, Altman D . Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986; 1(8476):307-10. View

2.
Wess G, Reusch C . Capillary blood sampling from the ear of dogs and cats and use of portable meters to measure glucose concentration. J Small Anim Pract. 2000; 41(2):60-6. DOI: 10.1111/j.1748-5827.2000.tb03164.x. View

3.
Martin G, Rand J . Evaluation of a polyurethane jugular catheter in cats placed using a modified Seldinger technique. Aust Vet J. 1999; 77(4):250-4. DOI: 10.1111/j.1751-0813.1999.tb11714.x. View

4.
Thompson M, Taylor S, Adams V, Waldner C, Feldman E . Comparison of glucose concentrations in blood samples obtained with a marginal ear vein nick technique versus from a peripheral vein in healthy cats and cats with diabetes mellitus. J Am Vet Med Assoc. 2002; 221(3):389-92. DOI: 10.2460/javma.2002.221.389. View

5.
Nelson R . Stress hyperglycemia and diabetes mellitus in cats. J Vet Intern Med. 2002; 16(2):121-2. DOI: 10.1892/0891-6640(2002)16<121:shadmi>2.0.co;2. View