Structure-function Relationships of Entheses in Relation to Mechanical Load and Exercise

Overview
Specialty Orthopedics
Date 2007 May 11
PMID 17490450
Citations 54
Authors
Affiliations
Soon will be listed here.
Abstract

Entheses are regions of high-stress concentration that are commonly affected by overuse injuries in sport. This review summarizes current knowledge of their structure-function relationships - at the macroscopic, microscopic and molecular levels. Consideration is given to how stress concentration is reduced at fibrocartilaginous entheses by various adaptations which ensure that stress is dissipated away from the hard-soft tissue interface. The fundamental question of how a tendon or ligament is anchored to bone is addressed - particularly in relation to the paucity of compact bone at fibrocartilaginous entheses. The concept of an "enthesis organ" is reviewed - i.e. the idea of a collection of tissues adjacent to the enthesis itself, which jointly serve a common function - stress dissipation. The archetypal enthesis organ is that of the Achilles tendon and the functional importance of its subtendinous bursa, with its fibrocartilaginous walls and protruding fat pad, is emphasized. The distribution of adipose tissue elsewhere at entheses is also explained and possible functions of insertion-site fat are evaluated. Finally, a brief consideration is given to enthesopathies, with attention drawn to the possibility of degenerative changes affecting other regions of an enthesis organ, besides the enthesis itself.

Citing Articles

Mature murine supraspinatus tendons demonstrate regional differences in multiscale structure, function and gene expression.

DiStefano M, Weiss S, Nuss C, Betts R, Han B, Kuntz A PLoS One. 2025; 20(2):e0318809.

PMID: 39977400 PMC: 11841869. DOI: 10.1371/journal.pone.0318809.


Gradient scaffolds in bone-soft tissue interface engineering: Structural characteristics, fabrication techniques, and emerging trends.

Liu Y, Wan Y, Li C, Guan G, Wang F, Gao J J Orthop Translat. 2025; 50:333-353.

PMID: 39944791 PMC: 11814525. DOI: 10.1016/j.jot.2024.10.015.


Repetitive Overuse Injury Causes Entheseal Damage and Palmar Muscle Fibrosis in Older Rats.

Patel P, Tamas I, Van Der Bas M, Kegg A, Hilliard B, Lambi A Int J Mol Sci. 2025; 25(24).

PMID: 39769311 PMC: 11679654. DOI: 10.3390/ijms252413546.


Dynamic Deformation Behavior of the Porcine Anterior Cruciate Ligament Enthesis Under Anterior Tibial Loading.

Ishii D, Sato S, Fujie H Ann Biomed Eng. 2024; 53(3):588-596.

PMID: 39604621 PMC: 11836234. DOI: 10.1007/s10439-024-03654-2.


GelMA encapsulating BMSCs-exosomes combined with interference screw or suture anchor promotes tendon-bone healing in a rabbit model.

Gao M, Zhao P, Xing J, Wang Z, Xu Y, Yan Y Sci Rep. 2024; 14(1):28212.

PMID: 39548341 PMC: 11568266. DOI: 10.1038/s41598-024-79787-0.