» Articles » PMID: 17477507

Gas-phase Interference-free Analysis of Protein Ion Charge-state Distributions: Detection of Small-scale Conformational Transitions Accompanying Pepsin Inactivation

Overview
Journal Anal Chem
Specialty Chemistry
Date 2007 May 5
PMID 17477507
Citations 18
Authors
Affiliations
Soon will be listed here.
Abstract

Analysis of protein ion charge-state distributions in electrospray ionization (ESI) mass spectra has become an indispensable tool in the studies of protein dynamics. However, applications of this technique have been thus far limited to detection of large-scale conformational transitions, which typically change the extent of multiple charging in a very significant way. However, more subtle conformational changes often elude detection, since the resulting changes of the extent of multiple charging are often smaller than the charge-state shifts caused by other external factors. Proton-transfer reactions involving protein ions and residual solvent molecules are the major extrinsic factors causing changes of charge-state distributions unrelated to conformational transitions. Since the extent of such reactions depends on the amount of various solvent components transferred to the ESI interface, profound changes of solvent composition may affect protein ion charge-state distributions not only by affecting protein higher order structure in solution but also through modulation of the efficiency of proton-transfer reactions in the gas phase. Here we demonstrate that it is possible to choose experimental conditions in such a way that the influence of gas-phase ion chemistry on protein ion charge-state distributions is not altered over a wide pH range. This methodology (gas-phase interference-free analysis of protein ion charge-state distributions, or GIFPICS) is sensitive enough to allow detection of pepsin inactivation under mildly acidic conditions. Pepsin is active and tightly folded in its native strongly acidic environment. Inactivation of pepsin at mildly acidic pH is not accompanied by global unfolding, as spectroscopic measurements suggest the protein remains compact. GIFPICS provides a means to observe this small-scale conformational transition that does not result in protein unfolding and may in fact elude detection by traditional spectroscopic techniques.

Citing Articles

Mass spectrometry-based methods to characterize highly heterogeneous biopharmaceuticals, vaccines, and nonbiological complex drugs at the intact-mass level.

Kaltashov I, Ivanov D, Yang Y Mass Spectrom Rev. 2022; 43(1):139-165.

PMID: 36582075 PMC: 10307928. DOI: 10.1002/mas.21829.


Extending the capabilities of intact-mass analyses to monoclonal immunoglobulins of the E-isotype (IgE).

Yang W, Ivanov D, Kaltashov I MAbs. 2022; 14(1):2103906.

PMID: 35895856 PMC: 9336480. DOI: 10.1080/19420862.2022.2103906.


Platelet Factor 4 Interactions with Short Heparin Oligomers: Implications for Folding and Assembly.

Niu C, Yang Y, Huynh A, Nazy I, Kaltashov I Biophys J. 2020; 119(7):1371-1379.

PMID: 32348723 PMC: 7567982. DOI: 10.1016/j.bpj.2020.04.012.


Top-down mass spectrometry of intact phosphorylated β-casein: Correlation between the precursor charge state and internal fragments.

Chen J, Shiyanov P, Green K J Mass Spectrom. 2019; 54(6):527-539.

PMID: 30997701 PMC: 6779312. DOI: 10.1002/jms.4364.


Resolving the Discrepancies Between Empirical and Rayleigh Charge Limiting Models for Globular Proteins.

De Freitas K J Am Soc Mass Spectrom. 2018; 29(10):2059-2066.

PMID: 30043359 DOI: 10.1007/s13361-018-2025-8.