Abstract

Background: Triage reliability studies typically use hypothetical scenarios and weighted kappa scores where agreement within one level is considered satisfactory. But if triage category is used to help define ED case-mix groups for comparative or benchmarking processes, agreement on exact triage level and major system involved is important. Our hypothesis was that a computerized menu that links presenting complaints to preferred triage levels (PC-linked triage) would provide high triage reliability.

Objectives: Our objective was to assess inter-rater reliability of PC-linked triage using the Canadian Emergency Department Triage and Acuity Scale (CTAS) in a real-time clinical setting, considering agreement on exact triage level and primary body system involved.

Methods: On duty triage nurses entered patient presenting complaint and PC-linked triage level as per standard procedure. In a convenience sample of patients, a second nurse, blinded to triage assignment, observed the triage interaction and independently entered presenting complaint and triage level on a dummy terminal.

Results: During the study, 15 nurse pairs triaged 266 patients. Study patients matched actual emergency department case mix closely. Triage nurses agreed exactly in 74% of cases and within one level in 94% of cases. The unweighted kappa value was 0.66 (95% confidence interval [CI], 0.60-0.73) and the quadratic weighted kappa value was 0.75 (95% CI, 0.68-0.81). Kappa for agreement on major system involved was 0.80 (95% CI, 0.69-0.91).

Conclusion: PC-linked triage has high inter-rater reliability in a real-time clinical setting. PC-linked triage may be useful as one factor in defining case-mix groups for benchmarking and comparative purposes.

Citing Articles

Changes in emergency department use in British Columbia, Canada, during the first 3 years of the COVID-19 pandemic.

Yao J, Irvine M, Klaver B, Zandy M, Dheri A, Grafstein E CMAJ. 2023; 195(34):E1141-E1150.

PMID: 37669788 PMC: 10480001. DOI: 10.1503/cmaj.221516.


Safety assessment of a redirection program using an electronic application for low-acuity patients visiting an emergency department.

Feral-Pierssens A, Morris J, Marquis M, Daoust R, Cournoyer A, Lessard J BMC Emerg Med. 2022; 22(1):71.

PMID: 35488215 PMC: 9052637. DOI: 10.1186/s12873-022-00626-4.


Characteristics of frequent emergency department users in British Columbia, Canada: a retrospective analysis.

Moe J, OSullivan F, McGregor M, Schull M, Dong K, Holroyd B CMAJ Open. 2021; 9(1):E134-E141.

PMID: 33653768 PMC: 8034376. DOI: 10.9778/cmajo.20200168.


Performance of a three-level triage scale in live triage encounters in an emergency department in Hong Kong.

Lam R, Kwok S, Chaang V, Chen L, Lau E, Chan K Int J Emerg Med. 2020; 13(1):28.

PMID: 32522272 PMC: 7288528. DOI: 10.1186/s12245-020-00288-8.


Electronic and manual registration of Manchester System: reliability, accuracy, and time evaluation.

Cicolo E, Peres H Rev Lat Am Enfermagem. 2019; 27:e3241.

PMID: 31826170 PMC: 6896810. DOI: 10.1590/1518-8345.3170.3241.