Enhancement of Vascular Permeability with Low-frequency Contrast-enhanced Ultrasound in the Chorioallantoic Membrane Model
Authors
Affiliations
Purpose: To characterize the effect of low-frequency contrast material-enhanced ultrasound on the vascular endothelium and to determine the parameters and techniques required to deliver a therapeutic agent by using the chorioallantoic membrane (CAM) model.
Materials And Methods: All in vivo animal procedures were conducted with institutional Animal Care and Use Committee approval. Extravasation of 8.5-nm-diameter fluorescein isothiocyanate-labeled dextran was evaluated in the vasculature of a chick CAM model. Intravital microscopy was performed during contrast-enhanced ultrasound exposure (1.00 or 2.25 MHz); results were compared with results of electron microscopy of the insonated regions. Data acquired after insonation with greater mechanical stress (n = 30 animals) (mechanical index [MI] > 1.3) and with lower mechanical stress (n = 86 animals) (MI < 1.13) were compared with measurements in control conditions (n = 46 animals). The diameter of affected vessels; number of extravasation sites; extravasation rate, area, and location; and changes in endothelial cells and basement membrane were evaluated. Differences were tested with analysis of variance or the Student t test.
Results: After ultrasound application, convective transport of the model drug was observed through micron-sized openings with a mean fluid velocity of 188.6 microm/sec in the low-stress class and 362.5 microm/sec in the high-stress class. Electron microscopy revealed micron-sized focal endothelial gaps and disseminated blebs, vacuoles, and filopodia extending across tens of microns. The threshold pressure for extravasation was 0.5 MPa for a transmitted center frequency of 1.00 MHz (MI = 0.5) and 1.6 MPa for a frequency of 2.25 MHz (MI = 1.06); thus, the frequency dependence of the threshold was not predicted simply by the MI.
Conclusion: Low-frequency contrast-enhanced ultrasound can increase vascular permeability and result in convective extravasation of an 8.5-nm-diameter model drug.
Jiang D, Qian Y, Gu Y, Wang R, Yu H, Wang Z Eur J Med Res. 2025; 30(1):66.
PMID: 39901203 PMC: 11789348. DOI: 10.1186/s40001-025-02292-1.
Shan H, Zheng G, Bao S, Yang H, Shrestha U, Li G Transl Oncol. 2024; 49:102115.
PMID: 39217852 PMC: 11402623. DOI: 10.1016/j.tranon.2024.102115.
In vivo high-speed microscopy of microbubbles in the chorioallantoic membrane model.
Anbarafshan R, Pellow C, Kiezun K, Leong H, Goertz D Theranostics. 2024; 14(5):1794-1814.
PMID: 38505609 PMC: 10945333. DOI: 10.7150/thno.91232.
Pellow C, Sojahrood A, Zhao X, Kolios M, Exner A, Goertz D ACS Nano. 2023; 18(1):410-427.
PMID: 38147452 PMC: 10786165. DOI: 10.1021/acsnano.3c07711.
Padilla F, Brenner J, Prada F, Klibanov A Theranostics. 2023; 13(12):4079-4101.
PMID: 37554276 PMC: 10405856. DOI: 10.7150/thno.70372.